A Sub‐Microsecond Switch Enabling <scp> SWIFT <sup>23</sup> Na </scp> Imaging at 10. <scp>5 T</scp>

PURPOSE: To enable sodium SWIFT imaging, which is a zero-echo time imaging technique, at ultra-high magnetic fields through the development of custom electronics hardware, and to showcase this capability with in vivo imaging results. METHODS: The custom hardware developed consists of a high-speed optical trigger with 10 ns resolution, an in-bore PIN diode driver capable of sourcing high current, and RF switches (both an in-line switchable attenuator and transmit/receive switch) optimized to achieve sub-microsecond switching speeds while also producing isolation between the transmitter and receiver. RESULTS: Practical switching speeds of 0.6 μs (receive to transmit) and 1.7 μs (transmit to receive) are achieved on the RF switches, limited by transient-induced spurious emissions from the low noise amplifier. Transmit to receive isolation of 115 dB is achieved over a 1 MHz bandwidth, with 120 dB of isolation at the Larmor frequency. This was crucial to suppress unblanked RFPA noise. SWIFT images of the human wrist with 1.5 mm isotropic resolution were acquired in less than 5 min to demonstrate the utility of sodium SWIFT imaging at ultra-high field. SWIFT imaging signal-to-noise ratio in a reference phantom with heterogeneous sodium concentrations was comparable to ultra-short echo time imaging, which provided assurance that hardware had achieved the necessary specifications. CONCLUSIONS: The feasibility of sodium SWIFT imaging at ultra-high field was established, and a musculoskeletal imaging application was demonstrated. The success of this work enables further development of SWIFT at high and ultra-high fields for imaging of sodium, proton, and other nuclei.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-06-08
DOI
https://doi.org/10.1002/mrm.70461
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Sub‐Microsecond Switch Enabling SWIFT 23 Na Imaging at 10. 5 T

Gregor Adriany, Russell Lagore, Jutta Ellermann, Edward J. Auerbach et al.
Magnetic Resonance in Medicine
Atomic and Subatomic Physics Research
article

A Sub‐Microsecond Switch Enabling SWIFT 23 Na Imaging at 10. 5 T

Gregor Adriany, Russell Lagore, Jutta Ellermann, Edward J. Auerbach, Steen Moeller, Gregory J. Metzger, Naoharu Kobayashi, Štefan Zbýň, Elnaz Mahmoudi Mahmoudalilou, Simon Schmidt, Christoph Schildknecht
article en

Abstract

PURPOSE: To enable sodium SWIFT imaging, which is a zero-echo time imaging technique, at ultra-high magnetic fields through the development of custom electronics hardware, and to showcase this capability with in vivo imaging results. METHODS: The custom hardware developed consists of a high-speed optical trigger with 10 ns resolution, an in-bore PIN diode driver capable of sourcing high current, and RF switches (both an in-line switchable attenuator and transmit/receive switch) optimized to achieve sub-microsecond switching speeds while also producing isolation between the transmitter and receiver. RESULTS: Practical switching speeds of 0.6 μs (receive to transmit) and 1.7 μs (transmit to receive) are achieved on the RF switches, limited by transient-induced spurious emissions from the low noise amplifier. Transmit to receive isolation of 115 dB is achieved over a 1 MHz bandwidth, with 120 dB of isolation at the Larmor frequency. This was crucial to suppress unblanked RFPA noise. SWIFT images of the human wrist with 1.5 mm isotropic resolution were acquired in less than 5 min to demonstrate the utility of sodium SWIFT imaging at ultra-high field. SWIFT imaging signal-to-noise ratio in a reference phantom with heterogeneous sodium concentrations was comparable to ultra-short echo time imaging, which provided assurance that hardware had achieved the necessary specifications. CONCLUSIONS: The feasibility of sodium SWIFT imaging at ultra-high field was established, and a musculoskeletal imaging application was demonstrated. The success of this work enables further development of SWIFT at high and ultra-high fields for imaging of sodium, proton, and other nuclei.

Magnetic Resonance in Medicine
University of Minnesota (US), Cleveland Clinic (US), German Cancer Research Center (DE), Heidelberg University (DE), Institute for Biomedical Engineering (CH), Resonance Research (United States) (US)
Openalex Percentile: Top 5%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.