Analysis of Faults in an Electric Power System

Electrical fault is an abnormal condition, caused by equipment failure, human errors and environmental conditions. These faults cause interruption to electric current flows, equipment damages and even death of humans, birds and animals. For example, a short circuit is a fault in which current bypasses the normal load. An open circuit fault occurs if a circuit is interrupted by some failures. In three phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a ground fault or earth fault, current flows into the earth. When fault occurs currents deviate from normal value. Bus impedance matrices are useful in the determination of these currents. This paper shows the analyses of a faulted power system using bus impedance matrices. The magnitudes of the currents during various fault conditions were determined for a particular power network. The results obtained show that the three-phase fault (symmetrical fault) has the highest fault current. These results enable the proper specification and optimal placing of circuit breakers for protection of the network.

Authors

Publication Details

Journal
Iconic Research and Engineering Journals
Published
2026-06-09
DOI
https://doi.org/10.64388/irev9i11-1717867
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Faults in an Electric Power System

Abba M O., Omeche A. A., E. E. Ezema
Iconic Research and Engineering Journals
Power Systems Fault Detection
article

Analysis of Faults in an Electric Power System

Abba M O., Omeche A. A., E. E. Ezema
article en

Abstract

Electrical fault is an abnormal condition, caused by equipment failure, human errors and environmental conditions. These faults cause interruption to electric current flows, equipment damages and even death of humans, birds and animals. For example, a short circuit is a fault in which current bypasses the normal load. An open circuit fault occurs if a circuit is interrupted by some failures. In three phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a ground fault or earth fault, current flows into the earth. When fault occurs currents deviate from normal value. Bus impedance matrices are useful in the determination of these currents. This paper shows the analyses of a faulted power system using bus impedance matrices. The magnitudes of the currents during various fault conditions were determined for a particular power network. The results obtained show that the three-phase fault (symmetrical fault) has the highest fault current. These results enable the proper specification and optimal placing of circuit breakers for protection of the network.

Iconic Research and Engineering JournalsVol. 9(11)
Openalex Percentile: Top 7%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Faults in an Electric Power System — Abba M O., Omeche A. A., et al. · Iconic Research and Engineering Journals (2026) | TGRS Research Map | TGRS