Experimental Validation of Skull Acoustic Modelling Strategies for Transcranial Focused Ultrasound Simulation: A Cross-Comparison Study

Abstract Objective Accurate acoustic modelling of the skull is important for simulation-guided transcranial focused ultrasound (tFUS) applications. However, existing skull parameterization strategies vary widely in complexity and reported accuracy. This study systematically evaluates commonly used modelling approaches to determine their predictive performance across multiple frequencies and skull types. Approach Five skull modelling strategies were assessed: two voxel-wise linear mapping models, one with fixed attenuation coefficient and one with Hounsfield unit (HU)-dependent attenuation coefficients; two three-layer models with fixed and skull-density ratio (SDR) dependent attenuation coefficient; and one single-layer fixed-parameter model. Nineteen regions of interest from five historical and two Thiel-embalmed human skulls were examined at 220 kHz, 680 kHz and 1000 kHz, bowl-surface source fields were reconstructed using holography, and intracranial pressure distributions were captured with a needle hydrophone. Measurements were compared with k-Wave simulations. Results Average simulated peak pressure errors (ɛp) ranged from 20% to 31% across frequencies, whereas intensity errors (ɛI) reached 41% to 81%. Errors in -6 dB focal volume ranged from 18% to 65%, and focal position discrepancies were typically several millimeters. Simulation generally predicted smaller insertion losses than measured, indicating a tendency to underestimate skull-related attenuation and overestimate transmitted intracranial exposure. Among the five modelling strategies, the model with the lowest observed error varied with frequency and outcome. Paired specimen-level comparisons did not establish a consistent accuracy advantage for any strategy. Significance These results indicate that current skull modelling strategies may reproduce the gross intracranial beam pattern while still misestimating the delivered acoustic exposure, focal coverage and localization. Such errors are directly relevant to tFUS dose selection, target coverage and safety-margin interpretation, underscoring the need for refined parameterization methods for reliable tFUS treatment planning.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-11-09
DOI
https://doi.org/10.1088/1361-6560/aebfe3
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental Validation of Skull Acoustic Modelling Strategies for Transcranial Focused Ultrasound Simulation: A Cross-Comparison Study

Aidan J. Horner, Han Li, Zhihong Huang
3 links
Physics in Medicine and Biology
Ultrasound and Hyperthermia Applications
article

Experimental Validation of Skull Acoustic Modelling Strategies for Transcranial Focused Ultrasound Simulation: A Cross-Comparison Study

Aidan J. Horner, Han Li, Zhihong Huang
article en

Abstract

Abstract Objective Accurate acoustic modelling of the skull is important for simulation-guided transcranial focused ultrasound (tFUS) applications. However, existing skull parameterization strategies vary widely in complexity and reported accuracy. This study systematically evaluates commonly used modelling approaches to determine their predictive performance across multiple frequencies and skull types. Approach Five skull modelling strategies were assessed: two voxel-wise linear mapping models, one with fixed attenuation coefficient and one with Hounsfield unit (HU)-dependent attenuation coefficients; two three-layer models with fixed and skull-density ratio (SDR) dependent attenuation coefficient; and one single-layer fixed-parameter model. Nineteen regions of interest from five historical and two Thiel-embalmed human skulls were examined at 220 kHz, 680 kHz and 1000 kHz, bowl-surface source fields were reconstructed using holography, and intracranial pressure distributions were captured with a needle hydrophone. Measurements were compared with k-Wave simulations. Results Average simulated peak pressure errors (ɛp) ranged from 20% to 31% across frequencies, whereas intensity errors (ɛI) reached 41% to 81%. Errors in -6 dB focal volume ranged from 18% to 65%, and focal position discrepancies were typically several millimeters. Simulation generally predicted smaller insertion losses than measured, indicating a tendency to underestimate skull-related attenuation and overestimate transmitted intracranial exposure. Among the five modelling strategies, the model with the lowest observed error varied with frequency and outcome. Paired specimen-level comparisons did not establish a consistent accuracy advantage for any strategy. Significance These results indicate that current skull modelling strategies may reproduce the gross intracranial beam pattern while still misestimating the delivered acoustic exposure, focal coverage and localization. Such errors are directly relevant to tFUS dose selection, target coverage and safety-margin interpretation, underscoring the need for refined parameterization methods for reliable tFUS treatment planning.

Physics in Medicine and Biology
University of York (GB)
University of Dundee
Good health and well-being
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon