Dual-Signal Direct Time-of-Flight Method for Long-Range Groundwater Level Monitoring in Observation Wells

Accurate and reliable groundwater-level monitoring in deep observation wells remains difficult for conventional non-contact ultrasonic systems because narrow tubular geometries intensify multipath reflections, signal attenuation, and echo ambiguity. This study proposes a dual-signal direct time-of-flight (ToF) method that combines radiofrequency (RF) synchronization with one-way airborne ultrasonic propagation to a floating receiver located at the groundwater surface. In the proposed architecture, the RF signal provides a near-instantaneous time reference, whereas the ultrasonic signal defines the propagation delay, thereby eliminating dependence on echo-based ranging. The system integrates a wellhead surface unit for synchronized transmission and control, a floating unit for ToF acquisition and embedded processing, and an optional reference channel for in situ estimation of the effective sound speed. A duty-cycled power architecture is used to support low-power long-term deployment, while a multi-shot acquisition strategy with a median-like estimator improves robustness against startup transients, timing jitters, and false detections. Field validation was conducted over a 12-month period under actual groundwater-monitoring conditions, during which the groundwater depth varied between 14 m and 30 m below the wellhead datum. Within this field-validation interval, the proposed system achieved a mean absolute error of 0.048 m, a maximum absolute error of 0.050 m, and an overall valid detection rate of 99.4% over 358 valid cycles out of 360 scheduled cycles. In addition, a separate range-dependent confined-tubular propagation test was conducted to evaluate the extended detection capability of the RF-synchronized one-way ultrasonic ToF architecture. This test demonstrated stable acoustic-link ToF detection up to 300 m inside the tested 170 mm confined plastic pipeline. Therefore, the 300 m result should be interpreted as a range-dependent valid-detection result rather than as a 12-month groundwater-depth validation over the full 300 m interval. These results demonstrate that the proposed direct-ToF method provides an RF-synchronized one-way ultrasonic ToF framework with a floating receiver for groundwater-level monitoring in deep observation wells, while remaining compatible with low-power and IoT-based environmental monitoring systems.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-06-09
DOI
https://doi.org/10.3390/s26123672
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-Signal Direct Time-of-Flight Method for Long-Range Groundwater Level Monitoring in Observation Wells

Khudoyorkhon Jamolov, Abror Shavkatovich Buriboev, Akmal Abduvaitov, Cheolwon Lee et al.
Sensors
Flow Measurement and Analysis
article

Dual-Signal Direct Time-of-Flight Method for Long-Range Groundwater Level Monitoring in Observation Wells

Khudoyorkhon Jamolov, Abror Shavkatovich Buriboev, Akmal Abduvaitov, Cheolwon Lee, Temur Azamov, I.R. Rahmatullayev, Jamoljon Djumanov, Farkhat Rajabov
article en

Abstract

Accurate and reliable groundwater-level monitoring in deep observation wells remains difficult for conventional non-contact ultrasonic systems because narrow tubular geometries intensify multipath reflections, signal attenuation, and echo ambiguity. This study proposes a dual-signal direct time-of-flight (ToF) method that combines radiofrequency (RF) synchronization with one-way airborne ultrasonic propagation to a floating receiver located at the groundwater surface. In the proposed architecture, the RF signal provides a near-instantaneous time reference, whereas the ultrasonic signal defines the propagation delay, thereby eliminating dependence on echo-based ranging. The system integrates a wellhead surface unit for synchronized transmission and control, a floating unit for ToF acquisition and embedded processing, and an optional reference channel for in situ estimation of the effective sound speed. A duty-cycled power architecture is used to support low-power long-term deployment, while a multi-shot acquisition strategy with a median-like estimator improves robustness against startup transients, timing jitters, and false detections. Field validation was conducted over a 12-month period under actual groundwater-monitoring conditions, during which the groundwater depth varied between 14 m and 30 m below the wellhead datum. Within this field-validation interval, the proposed system achieved a mean absolute error of 0.048 m, a maximum absolute error of 0.050 m, and an overall valid detection rate of 99.4% over 358 valid cycles out of 360 scheduled cycles. In addition, a separate range-dependent confined-tubular propagation test was conducted to evaluate the extended detection capability of the RF-synchronized one-way ultrasonic ToF architecture. This test demonstrated stable acoustic-link ToF detection up to 300 m inside the tested 170 mm confined plastic pipeline. Therefore, the 300 m result should be interpreted as a range-dependent valid-detection result rather than as a 12-month groundwater-depth validation over the full 300 m interval. These results demonstrate that the proposed direct-ToF method provides an RF-synchronized one-way ultrasonic ToF framework with a floating receiver for groundwater-level monitoring in deep observation wells, while remaining compatible with low-power and IoT-based environmental monitoring systems.

SensorsVol. 26(12)
Gachon University (KR), Samarkand State University named after Sharof Rashidov (UZ), Tashkent University of Information Technology (UZ), Konkuk University (KR), Tashkent Chemical-Technological Institute (UZ), Westminster International University in Tashkent (UZ)
Konkuk University, National Research Foundation of Korea
Clean water and sanitation
Openalex Percentile: Top 11%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.