Development and Preclinical Evaluation of <sup>68</sup> Ga-Labeled B7-H3-Specific Bicyclic Peptides as Immuno-PET Tracers for Oncology

B7-H3 (CD276) is an emerging target for cancer theranostics, highlighting the need for imaging probes capable of noninvasively quantifying B7-H3 expression in tumors. Here, we developed three 68 Ga-labeled B7-H3-targeting bicyclic peptide tracers with different PEG linker lengths. All tracers showed high radiochemical purity (>96%), favorable in vitro stability, and rapid blood clearance. Among them, [ 68 Ga]Ga-B7H3-FZ1 exhibited the highest affinity ( K D = 83.22 nM). Micro-PET/CT imaging demonstrated that tumor uptake of [ 68 Ga]Ga-B7H3-FZ1 correlated positively with B7-H3 expression across multiple tumor models. In H1299 tumors. B7-H3 overexpression increased uptake from 1.09 ± 0.18 to 3.50 ± 0.97%ID/g at 30 min postinjection, confirming target specificity. Biosafety studies indicated no obvious toxicity. These results support [ 68 Ga]Ga-B7H3-FZ1 as a promising PET tracer for noninvasive B7–H3 imaging.

Authors

Institutions

Publication Details

Journal
Journal of Medicinal Chemistry
Published
2026-06-09
DOI
https://doi.org/10.1021/acs.jmedchem.6c00961
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Preclinical Evaluation of 68 Ga-Labeled B7-H3-Specific Bicyclic Peptides as Immuno-PET Tracers for Oncology

Fengsheng Zhang, Jindian Li, Xuwei Liu, Simin He et al.
Journal of Medicinal Chemistry
Radiopharmaceutical Chemistry and Applications
article

Development and Preclinical Evaluation of 68 Ga-Labeled B7-H3-Specific Bicyclic Peptides as Immuno-PET Tracers for Oncology

Fengsheng Zhang, Jindian Li, Xuwei Liu, Simin He, Xiaoyu Pan, Shaoli Song, Hao Shen, Jianping Zhang, Dongliang Wang
article en

Abstract

B7-H3 (CD276) is an emerging target for cancer theranostics, highlighting the need for imaging probes capable of noninvasively quantifying B7-H3 expression in tumors. Here, we developed three 68 Ga-labeled B7-H3-targeting bicyclic peptide tracers with different PEG linker lengths. All tracers showed high radiochemical purity (>96%), favorable in vitro stability, and rapid blood clearance. Among them, [ 68 Ga]Ga-B7H3-FZ1 exhibited the highest affinity ( K D = 83.22 nM). Micro-PET/CT imaging demonstrated that tumor uptake of [ 68 Ga]Ga-B7H3-FZ1 correlated positively with B7-H3 expression across multiple tumor models. In H1299 tumors. B7-H3 overexpression increased uptake from 1.09 ± 0.18 to 3.50 ± 0.97%ID/g at 30 min postinjection, confirming target specificity. Biosafety studies indicated no obvious toxicity. These results support [ 68 Ga]Ga-B7H3-FZ1 as a promising PET tracer for noninvasive B7–H3 imaging.

Journal of Medicinal Chemistry
Shanghai Medical College of Fudan University (CN), Proton (Malaysia) (MY), Fudan University (CN), Fudan University Shanghai Cancer Center (CN), Laboratoire d’Imagerie Biomédicale (FR), Institute of Modern Physics (CN)
Shanghai Anti-Cancer Association, National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, Shanghai Hospital Development Center, State Key Laboratory of Oral Disease, Shanghai Key Laboratory of Molecular Imaging, Key Programme
Zero hunger
Openalex Percentile: Top 6%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.