Glycemic Responses to Two Different Exercise Modalities in Adolescents with Type 1 Diabetes Using Automated Insulin Delivery Systems: The AIDing Exercise Study

Objective: To examine the glycemic responses to two exercise modalities—high-intensity interval exercise (HIIE) and moderate-intensity continuous exercise (MICE)—when applying consensus guideline preexercise preparatory measures in adolescents with type 1 diabetes using automated insulin delivery (AID) systems. Research Design and Methods: In a two-period, crossover trial, 24 individuals (12 using MiniMed™ 780G and 12 using Tandem Control-IQ™) completed two experimental study days involving HIIE and MICE sessions. Participants were matched on age, sex, and total daily dose across AID systems. Continuous glucose monitoring (CGM) and insulin pump data were collected from participants’ AID systems. Plasma glucose (PG) was measured throughout the study days. Exercise was announced 60 min before MICE initiation, but not before HIIE. Results: No significant difference was observed for the primary outcome, CGM-derived time in range (TIR CGM : 3.9–10.0 mmol/L [70–180 mg/dL]), between study visits (HIIE: 91.7 [58.3–100.0] % vs. MICE: 83.3 [75.0–100.0] %, P = 0.261). Participants developed hypoglycemia during both visits (HIIE: 8 vs. MICE 11). When analyzed by the AID system, TIR PG (PG: 3.9–10.0 mmol/L [70–180 mg/dL]) was higher during MICE in the MiniMed™ 780G group, with no difference in the number of participants experiencing hypoglycemia at either visit. Conclusions: When applying consensus guideline preexercise recommendations, both exercise modalities achieved generally stable glycemic outcomes; however, hypoglycemia remained a challenge across study visits. These findings highlight that current AID systems still fall short of ensuring safe glycemic responses during exercise.

Authors

Institutions

Publication Details

Journal
Diabetes Technology & Therapeutics
Published
2026-06-08
DOI
https://doi.org/10.1177/15209156261456820
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Glycemic Responses to Two Different Exercise Modalities in Adolescents with Type 1 Diabetes Using Automated Insulin Delivery Systems: The AIDing Exercise Study

Jannet Svensson, Michael Zaucha Sørensen, Emilie Bundgaard Lindkvist, Ajenthen G. Ranjan et al.
Diabetes Technology & Therapeutics
Diabetes Management and Research
article

Glycemic Responses to Two Different Exercise Modalities in Adolescents with Type 1 Diabetes Using Automated Insulin Delivery Systems: The AIDing Exercise Study

Jannet Svensson, Michael Zaucha Sørensen, Emilie Bundgaard Lindkvist, Ajenthen G. Ranjan, Sandra Tawfik, Richard M. Bracken, Olivia M. McCarthy, Kirsten Nørgaard
article en

Abstract

Objective: To examine the glycemic responses to two exercise modalities—high-intensity interval exercise (HIIE) and moderate-intensity continuous exercise (MICE)—when applying consensus guideline preexercise preparatory measures in adolescents with type 1 diabetes using automated insulin delivery (AID) systems. Research Design and Methods: In a two-period, crossover trial, 24 individuals (12 using MiniMed™ 780G and 12 using Tandem Control-IQ™) completed two experimental study days involving HIIE and MICE sessions. Participants were matched on age, sex, and total daily dose across AID systems. Continuous glucose monitoring (CGM) and insulin pump data were collected from participants’ AID systems. Plasma glucose (PG) was measured throughout the study days. Exercise was announced 60 min before MICE initiation, but not before HIIE. Results: No significant difference was observed for the primary outcome, CGM-derived time in range (TIR CGM : 3.9–10.0 mmol/L [70–180 mg/dL]), between study visits (HIIE: 91.7 [58.3–100.0] % vs. MICE: 83.3 [75.0–100.0] %, P = 0.261). Participants developed hypoglycemia during both visits (HIIE: 8 vs. MICE 11). When analyzed by the AID system, TIR PG (PG: 3.9–10.0 mmol/L [70–180 mg/dL]) was higher during MICE in the MiniMed™ 780G group, with no difference in the number of participants experiencing hypoglycemia at either visit. Conclusions: When applying consensus guideline preexercise recommendations, both exercise modalities achieved generally stable glycemic outcomes; however, hypoglycemia remained a challenge across study visits. These findings highlight that current AID systems still fall short of ensuring safe glycemic responses during exercise.

Diabetes Technology & Therapeutics
University of Copenhagen (DK), Steno Diabetes Centers (DK), Swansea University (GB)
Good health and well-being
Openalex Percentile: Top 6%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.