Impact of Point-Spread Function Modeling on Image Quality in <sup>68</sup> Ga-PSMA PET/CT
The objective of this study was to evaluate the impact of 2 PET reconstruction methods—time of flight (TOF) and TOF with point-spread function (PSF) modeling (TOF + PSF)—on image quality and measured quantitative metrics in <sup>68</sup>Ga-PSMA PET/CT for prostate cancer. <b>Methods:</b> This retrospective analysis included 36 patients with prostate cancer who underwent <sup>68</sup>Ga-PSMA PET/CT at the Sultan Qaboos Comprehensive Cancer Care and Research Center between October 2022 and February 2024. PET data were reconstructed using TOF and TOF + PSF on a Biograph Vision 600 system. The quantitative parameters compared were SUV<sub>mean</sub>, prostate-specific membrane antigen tumor volume (PSMA-TV), total lesion uptake (TLU), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion-to-background ratio (LBR; lesion SUV<sub>mean</sub>/background SUV<sub>mean</sub>). Paired <i>t</i> tests or Wilcoxon signed-rank tests were used as appropriate, and agreement between reconstructions was assessed using Bland–Altman analysis. <b>Results:</b> Compared with TOF, TOF + PSF yielded a significantly higher SUV<sub>mean</sub> (mean difference, 1.41; 95% CI, 1.08–1.75; <i>P</i> < 0.001), SNR (mean difference, 23.31; 95% CI, 18.34–28.28; <i>P</i> < 0.001), CNR (mean difference, 23.54; 95% CI, 18.62–28.47; <i>P</i> < 0.001), LBR (mean difference, 8.0; 95% CI, 5.85–10.16; <i>P</i> < 0.0001), and TLU (mean difference, 3.62; 95% CI, 2.40–4.84; <i>P</i> < 0.001). PSMA-TV showed no significant difference between reconstructions (mean difference, 0.0052; 95% CI, −0.0154 to 0.0257; <i>P</i> = 0.626). Bland–Altman analysis demonstrated a systematic positive bias for TOF + PSF in SUV<sub>mean</sub>, SNR, CNR, LBR, and TLU. Because PSF modeling can increase SUV-based measurements via resolution recovery and edge effects, these increases should be interpreted as reconstruction-dependent changes in relative contrast rather than confirmed improvements in absolute quantitative accuracy without ground-truth validation. <b>Conclusion:</b> TOF + PSF reconstruction improves image quality and increases SUV-based and contrast-related metrics in <sup>68</sup>Ga-PSMA PET/CT and thus may enhance the conspicuity of small or low-contrast lesions. Phantom-based validation is recommended to determine the extent to which these reconstruction-dependent differences translate into improved absolute quantitative accuracy.
Authors
- Huda Al-Saidi
- Naema Al-Maymani
- Khulood Al-Riyami
- Amna Al-Jabri
- Subhash Chand Kheruka (ORCID: https://orcid.org/0000-0003-3807-1368)
- Noura Al-Makhmari
- Muhammad Sharjeel Usmani
- Anas Al-Balushi
- Sana Al-Rashdi
- Rashid Al-Sukaiti
- Anjali Jain
- Alyamama Al-Subhi
- Sura Al-Rawahi
Institutions
- Sultan Qaboos University Hospital (OM)
- Sultan Qaboos University (OM)
Publication Details
- Journal
- Journal of Nuclear Medicine Technology
- Published
- 2026-06-09
- DOI
- https://doi.org/10.2967/jnmt.125.271591
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00