Two-Stage Fault Diagnosis of Distribution Network Based on MS-CNN and Spatio-Temporal Dual Attention

Aiming at the problem of weak fault features and difficult localization of adjacent nodes in distribution networks, we constructed a two-stage cascaded architecture to decouple the diagnosis task into fault classification and section location. The feature layer fuses MS-CNN, SimAM, and Transformer to form a spatio-temporal dual attention mechanism that synchronously captures spatial saliency and global temporal logic. A prototype network is introduced at the fault location decision layer, and metric learning is used to solve the problem of feature aliasing of adjacent nodes. The experimental results show that the accuracy of fault classification and localization are 98.61% and 94.22%, respectively, and it exhibits graceful degradation under extremely low-SNR conditions, which verifies the effectiveness of the proposed strategy in the refined fault diagnosis of distribution networks.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-06-09
DOI
https://doi.org/10.3390/electronics15122545
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-Stage Fault Diagnosis of Distribution Network Based on MS-CNN and Spatio-Temporal Dual Attention

Jinyi Huang, Weijia Zheng, Hao Zhu, Ying Yang et al.
Electronics
Power Systems Fault Detection
article

Two-Stage Fault Diagnosis of Distribution Network Based on MS-CNN and Spatio-Temporal Dual Attention

Jinyi Huang, Weijia Zheng, Hao Zhu, Ying Yang, Zibin Cai
article en

Abstract

Aiming at the problem of weak fault features and difficult localization of adjacent nodes in distribution networks, we constructed a two-stage cascaded architecture to decouple the diagnosis task into fault classification and section location. The feature layer fuses MS-CNN, SimAM, and Transformer to form a spatio-temporal dual attention mechanism that synchronously captures spatial saliency and global temporal logic. A prototype network is introduced at the fault location decision layer, and metric learning is used to solve the problem of feature aliasing of adjacent nodes. The experimental results show that the accuracy of fault classification and localization are 98.61% and 94.22%, respectively, and it exhibits graceful degradation under extremely low-SNR conditions, which verifies the effectiveness of the proposed strategy in the refined fault diagnosis of distribution networks.

ElectronicsVol. 15(12)
Foshan University (CN), Zhaoqing University (CN), Power Grid Corporation (India) (IN)
China Southern Power Grid
Openalex Percentile: Top 7%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.