Patient‐Reported Outcome Measures Following Pulsed‐Field Ablation Versus Thermal Ablation of Atrial Fibrillation: The PROMs‐PFA Study
BACKGROUND: Pulsed-field ablation (PFA) has transformed atrial fibrillation (AF) ablation, but how the early patient experience compares with thermal techniques remains unclear. This study aimed to assess patient-reported outcome measures (PROMs) in the first 3 months after PFA or thermal AF ablation, using a novel smartphone-based application. METHODS: Patients undergoing first-time pulmonary vein isolation prospectively completed the Cardiac Ablation Recovery Evaluation (CARE) symptom questionnaire at five timepoints: baseline, day 1, day 7, day 30, and day 90. Symptoms were rated on a 7-point Likert scale (0 = not at all; 6 = extremely). Patients also completed the Atrial Fibrillation Effect on QualiTy-of-life (AFEQT) questionnaire at baseline and day 90. RESULTS: Two hundred and two patients were included (pentaspline PFA: 66; radiofrequency: 64; cryoballoon: 72), with similar baseline demographics between groups, except for a lower prevalence of paroxysmal AF in the PFA group. Engagement with the smartphone-based platform was high, with a 94.7% completion rate. Median AFEQT scores improved from 64 (47-82) at baseline to 86 (72-95) at day 90 (p < 0.001), with no significant differences between modalities (p = 0.841). However, CARE detected differences in early symptom experience: chest pain was lowest with PFA at day 1 (median: PFA, 1 [0-2]; radiofrequency, 2 [1-2]; cryoballoon, 2 [1-2]; p < 0.001), and remained lower than cryoballoon at day 7 (p = 0.019), with differences resolving by day 30. Moderate-to-severe chest pain (score ≥ 3) occurred in only 12.3% of PFA patients at day 1, compared with 21.2% cryoballoon and 26.2% radiofrequency patients (p < 0.001). Palpitations at day 1 were less frequent with PFA than radiofrequency (p = 0.040). Groin discomfort was lower with radiofrequency than PFA or cryoballoon at day 1 (p = 0.006) and day 7 (p < 0.001), likely reflecting a smaller sheath size. CONCLUSIONS: PFA was associated with a modest and transient reduction in early post-procedural chest pain compared with thermal ablation. Smartphone application-based PROMs collection using the CARE questionnaire was feasible, enabling structured assessment of symptom burden across multiple recovery timepoints.
Authors
- Peter Calvert (ORCID: https://orcid.org/0000-0002-8401-4033)
- Zoltan Borbas (ORCID: https://orcid.org/0000-0001-5648-7418)
- R Ashrafi
- Vishal Luther (ORCID: https://orcid.org/0000-0003-3274-7128)
- Saagar Mahida (ORCID: https://orcid.org/0000-0002-0072-3298)
- Keith Wilson
- Nathan Denham
- Simon Modi
- Johan Waktare
- Mark T. Mills
- Derick Todd
- Richard Snowdon
- Dhiraj Gupta
Institutions
- University of Liverpool (GB)
- Liverpool Heart and Chest Hospital (GB)
- Sheffield Teaching Hospitals NHS Foundation Trust (GB)
Publication Details
- Journal
- Journal of Cardiovascular Electrophysiology
- Published
- 2026-06-09
- DOI
- https://doi.org/10.1111/jce.70392
- Primary Topic
- Atrial Fibrillation Management and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00