How Successful Are Meniscus Repair All-Inside Implants During Deployment?

INTRODUCTION: The purpose of this study was to determine the percentage of implants successfully deployed during arthroscopic all-inside meniscal repair. METHODS: A data query of meniscus repair (CPT codes: 29882 and 29883) procedures was performed at a single institution. The query was limited to include procedures performed between June 1, 2020 and June 1, 2023. Multiple different manufacturer implants were used by 5 sports medicine fellowship trained orthopaedic surgeons. The number of implants successfully used and number of implants wasted due to intra-operative failure during meniscal repair were found on EPIC and documented for each procedure. Success rate of meniscal implants was determined by dividing the number of implants wasted by the total amount of implants used. RESULTS: The query identified 1,026 patients that underwent meniscus repair. From this cohort, 3,867 total meniscal implants were utilized for an average of 3.77 implants per case. Overall, all inside meniscus repair was found to have a low implant failure or waste rate (1.03% [n = 40]). The highest failure rates were found with JuggerStitchTM Curved (9.38%), NOVOSTITCHTM Cartridge 0 Suture (2.44%), and TRUESPANTM 12 Degrees (2.11%) implants. CONCLUSIONS: The most important finding was that the overall failure rate of meniscal implants is low. Implants with higher waste rates should be addressed by industry and considered by surgeons when selecting surgical implants. These preliminary findings establish the necessity to further examine implant failure rate and associated costs of meniscus repair.

Authors

Institutions

Publication Details

Journal
The Journal of Knee Surgery
Published
2026-06-09
DOI
https://doi.org/10.1055/a-2886-8226
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

How Successful Are Meniscus Repair All-Inside Implants During Deployment?

Sonu Bae, Tyler Barker, Emma Flanigan, David C Flanigan
The Journal of Knee Surgery
Knee injuries and reconstruction techniques
article

How Successful Are Meniscus Repair All-Inside Implants During Deployment?

Sonu Bae, Tyler Barker, Emma Flanigan, David C Flanigan
article en

Abstract

INTRODUCTION: The purpose of this study was to determine the percentage of implants successfully deployed during arthroscopic all-inside meniscal repair. METHODS: A data query of meniscus repair (CPT codes: 29882 and 29883) procedures was performed at a single institution. The query was limited to include procedures performed between June 1, 2020 and June 1, 2023. Multiple different manufacturer implants were used by 5 sports medicine fellowship trained orthopaedic surgeons. The number of implants successfully used and number of implants wasted due to intra-operative failure during meniscal repair were found on EPIC and documented for each procedure. Success rate of meniscal implants was determined by dividing the number of implants wasted by the total amount of implants used. RESULTS: The query identified 1,026 patients that underwent meniscus repair. From this cohort, 3,867 total meniscal implants were utilized for an average of 3.77 implants per case. Overall, all inside meniscus repair was found to have a low implant failure or waste rate (1.03% [n = 40]). The highest failure rates were found with JuggerStitchTM Curved (9.38%), NOVOSTITCHTM Cartridge 0 Suture (2.44%), and TRUESPANTM 12 Degrees (2.11%) implants. CONCLUSIONS: The most important finding was that the overall failure rate of meniscal implants is low. Implants with higher waste rates should be addressed by industry and considered by surgeons when selecting surgical implants. These preliminary findings establish the necessity to further examine implant failure rate and associated costs of meniscus repair.

The Journal of Knee Surgery
The Ohio State University Wexner Medical Center (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 6%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

How Successful Are Meniscus Repair All-Inside Implants During Deployment? — Sonu Bae, Tyler Barker, et al. · The Journal of Knee Surgery (2026) | TGRS Research Map | TGRS