A two-stage pressure ramping strategy for improving the efficacy of sonothrombolysis: Insights from a microbubble dynamics study

Sonothrombolysis is a technique that utilises ultrasound waves and microbubbles to remove blood clots. When insonated with high-pressure ultrasound waves, microbubbles undergo inertial cavitation and collapse violently to form high-speed jets. If this phenomenon occurs near the clot, the shear stress resulting from the jet impact can lead to considerable mechanical erosion of the clot surface. Efforts to enhance shear stress by optimising treatment parameters are limited by the trade-off between jet velocity and the distance travelled by the microbubble. Increasing jet velocity usually shortens the distance travelled, while extending the distance travelled often reduces jet velocity. In this study, a two-stage insonation scheme via a pressure ramping strategy was proposed to address this issue. In the first stage, low-pressure insonation enables stable oscillation and translation of the microbubble towards the clot. The pressure was then increased in the following stage to trigger inertial cavitation. Numerical findings indicated that the pressure ramping strategy can produce shear stress of 702 kPa with a ramped-up pressure of only 400 kPa. This surpasses the 487 kPa achieved without pressure ramping at a pressure magnitude of 1000 kPa. The elevated shear stress resulting from pressure ramping is due to the significant movement of the microbubble towards the clot during the initial insonation phase that utilises low pressure. In addition to enhancing shear stress, pressure ramping also facilitates drug penetration as the jet penetrates the clot. Therefore, pressure ramping may serve as an effective strategy to improve the effectiveness of sonothrombolysis.

Authors

Institutions

Publication Details

Journal
Journal of Applied Biomedicine
Published
2026-06-09
DOI
https://doi.org/10.1016/j.bbe.2026.05.005
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A two-stage pressure ramping strategy for improving the efficacy of sonothrombolysis: Insights from a microbubble dynamics study

Zhi Q. Tan, Ean Hin Ooi, Ean T. Ooi, Jing Y. Yip
Journal of Applied Biomedicine
Ultrasound and Hyperthermia Applications
article

A two-stage pressure ramping strategy for improving the efficacy of sonothrombolysis: Insights from a microbubble dynamics study

Zhi Q. Tan, Ean Hin Ooi, Ean T. Ooi, Jing Y. Yip
article en

Abstract

Sonothrombolysis is a technique that utilises ultrasound waves and microbubbles to remove blood clots. When insonated with high-pressure ultrasound waves, microbubbles undergo inertial cavitation and collapse violently to form high-speed jets. If this phenomenon occurs near the clot, the shear stress resulting from the jet impact can lead to considerable mechanical erosion of the clot surface. Efforts to enhance shear stress by optimising treatment parameters are limited by the trade-off between jet velocity and the distance travelled by the microbubble. Increasing jet velocity usually shortens the distance travelled, while extending the distance travelled often reduces jet velocity. In this study, a two-stage insonation scheme via a pressure ramping strategy was proposed to address this issue. In the first stage, low-pressure insonation enables stable oscillation and translation of the microbubble towards the clot. The pressure was then increased in the following stage to trigger inertial cavitation. Numerical findings indicated that the pressure ramping strategy can produce shear stress of 702 kPa with a ramped-up pressure of only 400 kPa. This surpasses the 487 kPa achieved without pressure ramping at a pressure magnitude of 1000 kPa. The elevated shear stress resulting from pressure ramping is due to the significant movement of the microbubble towards the clot during the initial insonation phase that utilises low pressure. In addition to enhancing shear stress, pressure ramping also facilitates drug penetration as the jet penetrates the clot. Therefore, pressure ramping may serve as an effective strategy to improve the effectiveness of sonothrombolysis.

Journal of Applied BiomedicineVol. 46(3)
Monash University Malaysia (MY), Federation University (AU)
Openalex Percentile: Top 11%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A two-stage pressure ramping strategy for improving the efficacy of sonothrombolysis: Insights from a microbubble dynamics study — Zhi Q. Tan, Ean Hin Ooi, et al. · Journal of Applied Biomedicine (2026) | TGRS Research Map | TGRS