Monte Carlo simulations of optical propagation in human skin using experimentally measured laser parameters

To simulate light propagation in human skin irradiated with laser sources emitting at 660 nm, 830 nm, and 904 nm, using different beam diameters and divergences, in order to characterize the internal fluence rate distribution profiles within the tissue. Monte Carlo simulations were performed using the GPU-accelerated MCX platform. Optical properties (absorption and reduced scattering coefficients) were experimentally obtained from human skin samples and incorporated into a three-dimensional voxel-based model. Laser parameters, including output power, beam radius, and divergence, were experimentally characterized and used as input for simulations. The effects of wavelength, beam divergence, and source radius on axial and spatial fluence rate distribution were quantitatively evaluated under controlled power conditions. All wavelengths exhibited exponential attenuation with comparable depth-dependent behavior within the first millimeters of tissue. Beam radius significantly modulated surface peak fluence rate and central-axis magnitude at depth under constant total power. In contrast, real divergence values typical of commercial devices produced minimal changes in axial fluence under contact-mode conditions, whereas large theoretical divergence angles markedly reduced fluence retention and increased lateral spread. Among the investigated variables, beam radius exerted the strongest influence on subsurface fluence magnitude under constant power, whereas wavelengths within the therapeutic window (660-904 nm) showed comparable attenuation behavior in superficial tissue. Realistic divergence values typical of commercial devices minimally affected axial fluence under contact-mode conditions, while larger angular spreads significantly reduced central-axis fluence retention.

Authors

Institutions

Publication Details

Journal
Lasers in Medical Science
Published
2026-06-09
DOI
https://doi.org/10.1007/s10103-026-04911-7
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monte Carlo simulations of optical propagation in human skin using experimentally measured laser parameters

Luciano Bachmann, Murilo S. Sampaio, Carlos Eduardo Girasol, Raissa Mendonça Quaranta Lobão et al.
Lasers in Medical Science
Optical Imaging and Spectroscopy Techniques
article

Monte Carlo simulations of optical propagation in human skin using experimentally measured laser parameters

Luciano Bachmann, Murilo S. Sampaio, Carlos Eduardo Girasol, Raissa Mendonça Quaranta Lobão, Rinaldo Roberto de Jesus Guirro, Luismar Barbosa Cruz-Junior
article en

Abstract

To simulate light propagation in human skin irradiated with laser sources emitting at 660 nm, 830 nm, and 904 nm, using different beam diameters and divergences, in order to characterize the internal fluence rate distribution profiles within the tissue. Monte Carlo simulations were performed using the GPU-accelerated MCX platform. Optical properties (absorption and reduced scattering coefficients) were experimentally obtained from human skin samples and incorporated into a three-dimensional voxel-based model. Laser parameters, including output power, beam radius, and divergence, were experimentally characterized and used as input for simulations. The effects of wavelength, beam divergence, and source radius on axial and spatial fluence rate distribution were quantitatively evaluated under controlled power conditions. All wavelengths exhibited exponential attenuation with comparable depth-dependent behavior within the first millimeters of tissue. Beam radius significantly modulated surface peak fluence rate and central-axis magnitude at depth under constant total power. In contrast, real divergence values typical of commercial devices produced minimal changes in axial fluence under contact-mode conditions, whereas large theoretical divergence angles markedly reduced fluence retention and increased lateral spread. Among the investigated variables, beam radius exerted the strongest influence on subsurface fluence magnitude under constant power, whereas wavelengths within the therapeutic window (660-904 nm) showed comparable attenuation behavior in superficial tissue. Realistic divergence values typical of commercial devices minimally affected axial fluence under contact-mode conditions, while larger angular spreads significantly reduced central-axis fluence retention.

Lasers in Medical ScienceVol. 41(1)
Universidade de Ribeirão Preto (BR), Universidade do Estado de Santa Catarina (BR), Universidade de São Paulo (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Universidade do Estado de Santa Catarina
Openalex Percentile: Top 6%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.