Deep-learning based image reconstruction enables reduced dose CT pulmonary angiography with non-inferior image quality

To investigate whether a CT pulmonary angiography (CTPA) protocol with reduced radiation dose and deep-learning based image reconstruction (DLIR) is non-inferior in image quality to standard-dose CTPA using iterative reconstruction. A phantom study was conducted to estimate the additional radiation dose reduction enabled by high-strength deep learning-based image reconstruction (DLIR-H) compared to adaptive statistical iterative reconstruction (ASiR-V 90%). Medium and large phantoms were used to simulate different body sizes. Subsequently, we reduced radiation dose of our clinical CTPA protocol and transitioned to DLIR for image reconstruction. We retrospectively analyzed 307 consecutive patients who were examined before (n = 152) and after (n = 155) this clinically driven change in the CTPA protocol. Objective image quality was quantified and subjective image quality was rated by two radiologists. The non-inferiority margin was pre-specified as a < 5% difference in image quality parameters. In the phantom, DLIR-H allowed radiation dose to be reduced by up to 71% with equivalent or higher signal-to-noise-ratio (SNR) compared to standard-dose examinations reconstructed with ASiR-V 90%. In the patient cohort, radiation dose was reduced by 41% (median DLP 116 vs. 68 mGy*cm; effective dose 1.69 vs. 0.99 mSv, p < 0.001). In the modified protocol, median SNR was superior for the central pulmonary artery (13.6 vs. 22.3) and non-inferior for the segmental pulmonary arteries (16.4 vs. 16.8). Subjective image quality averaged over both readers was superior with the modified protocol. Compared to state-of-the-art iterative reconstruction, DLIR allows radiation dose for CTPA to be reduced by an additional 41% with non-inferior image quality.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-09
DOI
https://doi.org/10.1038/s41598-026-56545-y
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep-learning based image reconstruction enables reduced dose CT pulmonary angiography with non-inferior image quality

Ann‐Christin Klemenz, Mathias Manzke, Sina Sender, Matthias Lütgens et al.
Scientific Reports
Radiation Dose and Imaging
article

Deep-learning based image reconstruction enables reduced dose CT pulmonary angiography with non-inferior image quality

Ann‐Christin Klemenz, Mathias Manzke, Sina Sender, Matthias Lütgens, Tobias Geyer, J Hillebrand, R Lorbeer, Marc-André Weber, Paul J. Böttcher, Felix G. Meinel
article en

Abstract

To investigate whether a CT pulmonary angiography (CTPA) protocol with reduced radiation dose and deep-learning based image reconstruction (DLIR) is non-inferior in image quality to standard-dose CTPA using iterative reconstruction. A phantom study was conducted to estimate the additional radiation dose reduction enabled by high-strength deep learning-based image reconstruction (DLIR-H) compared to adaptive statistical iterative reconstruction (ASiR-V 90%). Medium and large phantoms were used to simulate different body sizes. Subsequently, we reduced radiation dose of our clinical CTPA protocol and transitioned to DLIR for image reconstruction. We retrospectively analyzed 307 consecutive patients who were examined before (n = 152) and after (n = 155) this clinically driven change in the CTPA protocol. Objective image quality was quantified and subjective image quality was rated by two radiologists. The non-inferiority margin was pre-specified as a < 5% difference in image quality parameters. In the phantom, DLIR-H allowed radiation dose to be reduced by up to 71% with equivalent or higher signal-to-noise-ratio (SNR) compared to standard-dose examinations reconstructed with ASiR-V 90%. In the patient cohort, radiation dose was reduced by 41% (median DLP 116 vs. 68 mGy*cm; effective dose 1.69 vs. 0.99 mSv, p < 0.001). In the modified protocol, median SNR was superior for the central pulmonary artery (13.6 vs. 22.3) and non-inferior for the segmental pulmonary arteries (16.4 vs. 16.8). Subjective image quality averaged over both readers was superior with the modified protocol. Compared to state-of-the-art iterative reconstruction, DLIR allows radiation dose for CTPA to be reduced by an additional 41% with non-inferior image quality.

Scientific ReportsVol. 16(1)
University of Rostock (DE), Ludwig-Maximilians-Universität München (DE)
Bundesministerium für Bildung und Forschung
Openalex Percentile: Top 6%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.