A Quantitative Efflux Ratio-Integrated Model for Passive PermeabilityEstimation from Caco-2 Assays

INTRODUCTION/OBJECTIVE: Reliable estimation of passive permeability in the presence of active efflux remains a key challenge in early drug discovery. In bidirectional Caco-2 assays, apparent permeability reflects both passive diffusion and transporter-mediated efflux, preventing direct determination of intrinsic passive permeability from baseline measurements. Existing approaches typically require additional experimental systems, increasing complexity and cost. This study aimed to develop a quantitative method to estimate passive permeability directly from standard Caco-2 data without additional assays. METHODS: An empirical Efflux Ratio Integrated Model (ERIM) was developed, incorporating Efflux Ratio (ER) into a correction framework applied to bidirectional apparent permeability data. The model was evaluated using a dataset of 125 in-house compounds and 13 reference compounds. Performance was assessed through repeated train-test validation, comparison with a Global Average Model (GAM), and classification-based error analysis. RESULTS: GAM showed systematic overestimation of passive permeability that increased with ER, resulting in a high false-positive rate. ERIM eliminated efflux-dependent bias, substantially reduced false-positive classifications, and maintained low false-negative rates, with consistent performance across validation rounds. DISCUSSION: The conventional averaging method (GAM) showed that efflux-driven distortion on passive permeability estimate is systematic and can be corrected using ER and a scaling factor. Results showed reduced bias without increasing false negatives, supporting its utility for early-stage screening. CONCLUSION: ERIM provides a simple and practical framework for estimating passive permeability directly from a single Caco-2 assay by correcting efflux-related bias. This approach improves the interpretability of permeability data and supports more efficient compound prioritization in early-stage drug discovery.

Authors

Institutions

Publication Details

Journal
Drug Metabolism and Bioanalysis
Published
2026-06-08
DOI
https://doi.org/10.2174/0131173853500625260530130306
Primary Topic
Computational Drug Discovery Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Quantitative Efflux Ratio-Integrated Model for Passive PermeabilityEstimation from Caco-2 Assays

Grace Zang, Tao Zhang, Chunyan Han, Kent Wong et al.
Drug Metabolism and Bioanalysis
Computational Drug Discovery Methods
article

A Quantitative Efflux Ratio-Integrated Model for Passive PermeabilityEstimation from Caco-2 Assays

Grace Zang, Tao Zhang, Chunyan Han, Kent Wong, Xin Wang, Zhongyuan Zhao
article en

Abstract

INTRODUCTION/OBJECTIVE: Reliable estimation of passive permeability in the presence of active efflux remains a key challenge in early drug discovery. In bidirectional Caco-2 assays, apparent permeability reflects both passive diffusion and transporter-mediated efflux, preventing direct determination of intrinsic passive permeability from baseline measurements. Existing approaches typically require additional experimental systems, increasing complexity and cost. This study aimed to develop a quantitative method to estimate passive permeability directly from standard Caco-2 data without additional assays. METHODS: An empirical Efflux Ratio Integrated Model (ERIM) was developed, incorporating Efflux Ratio (ER) into a correction framework applied to bidirectional apparent permeability data. The model was evaluated using a dataset of 125 in-house compounds and 13 reference compounds. Performance was assessed through repeated train-test validation, comparison with a Global Average Model (GAM), and classification-based error analysis. RESULTS: GAM showed systematic overestimation of passive permeability that increased with ER, resulting in a high false-positive rate. ERIM eliminated efflux-dependent bias, substantially reduced false-positive classifications, and maintained low false-negative rates, with consistent performance across validation rounds. DISCUSSION: The conventional averaging method (GAM) showed that efflux-driven distortion on passive permeability estimate is systematic and can be corrected using ER and a scaling factor. Results showed reduced bias without increasing false negatives, supporting its utility for early-stage screening. CONCLUSION: ERIM provides a simple and practical framework for estimating passive permeability directly from a single Caco-2 assay by correcting efflux-related bias. This approach improves the interpretability of permeability data and supports more efficient compound prioritization in early-stage drug discovery.

Drug Metabolism and BioanalysisVol. 19
Binghamton University (US), University of California, Los Angeles (US), Ideaya Biosciences (United States) (US), Pharmaron (United Kingdom) (GB)
Openalex Percentile: Top 4%
Computational Drug Discovery Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.