Explainable Quality Assessment and Measurement from Real-World Hip Ultrasound Cine Sweeps

This study evaluates Retuve, an open-source explainable pipeline for the automated analysis of infant hip ultrasound cine sweeps. Retuve combines segmentation, Graf-plane calibration, and frame filtering. In a retrospective multicenter study, we tested the full pipeline on an external set of 109 hips from a Canadian community clinic, with internal developmental validation of segmentation on 90 hips and Graf-plane calibration on 419 hips. On the external test set, Retuve achieved 100% specificity and 91% sensitivity for expert agreement regarding whether a sweep contained an analyzable frame, compared with 75% specificity and 96% sensitivity for a radiology fellow; specificity was based on 16 expert-negative examinations. For alpha angle and acetabular coverage, Retuve achieved consistency intraclass correlation coefficients (ICCs) of 0.77 and 0.74, comparable to the fellow’s 0.70 and 0.74. However, alpha-angle absolute agreement was lower (ICC 0.55, 95% confidence interval (CI) −0.07–0.81), consistent with systematic measurement bias. Internal developmental validation showed Component 1 mask mean average precision at 50% intersection-over-union (mAP50) of 0.753 and box mAP50 of 0.883 and a Component 2 ICC of 0.792. Retuve can select analyzable frames and recover measurements from variable-quality cine sweeps, but alpha-angle calibration requires refinement. Future prospective work should evaluate developmental dysplasia of the hip (DDH) diagnostic accuracy, clinical treatment decision support, and screening outcomes.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-06-08
DOI
https://doi.org/10.3390/bioengineering13060667
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Explainable Quality Assessment and Measurement from Real-World Hip Ultrasound Cine Sweeps

Stephen Burnside, Adam McArthur, Stephanie Wichuk, Abhilash Hareendranathan et al.
Bioengineering
Hip disorders and treatments
article

Explainable Quality Assessment and Measurement from Real-World Hip Ultrasound Cine Sweeps

Stephen Burnside, Adam McArthur, Stephanie Wichuk, Abhilash Hareendranathan, Sukhdeep Dulai, George Reed, Jacob L. Jaremko
article en

Abstract

This study evaluates Retuve, an open-source explainable pipeline for the automated analysis of infant hip ultrasound cine sweeps. Retuve combines segmentation, Graf-plane calibration, and frame filtering. In a retrospective multicenter study, we tested the full pipeline on an external set of 109 hips from a Canadian community clinic, with internal developmental validation of segmentation on 90 hips and Graf-plane calibration on 419 hips. On the external test set, Retuve achieved 100% specificity and 91% sensitivity for expert agreement regarding whether a sweep contained an analyzable frame, compared with 75% specificity and 96% sensitivity for a radiology fellow; specificity was based on 16 expert-negative examinations. For alpha angle and acetabular coverage, Retuve achieved consistency intraclass correlation coefficients (ICCs) of 0.77 and 0.74, comparable to the fellow’s 0.70 and 0.74. However, alpha-angle absolute agreement was lower (ICC 0.55, 95% confidence interval (CI) −0.07–0.81), consistent with systematic measurement bias. Internal developmental validation showed Component 1 mask mean average precision at 50% intersection-over-union (mAP50) of 0.753 and box mAP50 of 0.883 and a Component 2 ICC of 0.792. Retuve can select analyzable frames and recover measurements from variable-quality cine sweeps, but alpha-angle calibration requires refinement. Future prospective work should evaluate developmental dysplasia of the hip (DDH) diagnostic accuracy, clinical treatment decision support, and screening outcomes.

BioengineeringVol. 13(6)
University of Alberta (CA)
Peace, Justice and strong institutions
Openalex Percentile: Top 5%
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.