Advanced Fault Detection of Permanent Magnet Faults in Offshore Wind Turbine Generators Using Finite Element Analysis and Deep Transfer Learning

As the offshore wind industry scales toward 15 MW capacity, the reliability of Direct-Drive Permanent Magnet Synchronous Generators (DD-PMSGs) becomes critical. However, real-world run-to-failure data for these massive, multi-pole machines is virtually non-existent, creating a barrier for developing effective data-driven diagnostic systems. This study proposes a high-fidelity framework for detecting permanent magnet faults in the International Energy Agency (IEA) 15 MW Reference Wind Turbine. Using Finite Element Analysis (FEA), a dataset (magnetic flux and back electromotive-force (EMF)) capturing the electromagnetic signatures of healthy and faulty states of a PMSG under varying severities is generated. To improve the power of computer vision, 1D time-series signals were transformed into 2D images. Specifically, Gramian Angular Fields (GAFs) and Recurrence Plots (RPs) were applied to magnetic flux density signals, while Markov Transition Fields (MTFs) were applied to back-EMF signals. These representations were then fused into multi-channel Red-Green-Blue (RGB) images and processed via a ResNet-18 Deep Transfer Learning model using a strictly non-overlapping, leakage-free dataset partitioning strategy. The proposed framework achieved a classification accuracy of 99.45% on noise-free data. Furthermore, robustness testing under varying levels of Additive White Gaussian Noise (AWGN) (30 dB, 40 dB, and 50 dB Signal-to-Noise Ratio (SNR)) demonstrated sustained high performance, maintaining over 90% accuracy even under severe 30 dB noise conditions. Comparative analysis proved that this multi-channel fusion significantly outperforms single-channel encoding methods, which collapse under heavy noise, validating the scalability of the framework and applicability for next-generation condition monitoring in harsh offshore environments.

Authors

Institutions

Publication Details

Journal
Machines
Published
2026-06-08
DOI
https://doi.org/10.3390/machines14060665
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Fault Detection of Permanent Magnet Faults in Offshore Wind Turbine Generators Using Finite Element Analysis and Deep Transfer Learning

Hüseyin Tayyer Canseven, Nur Sarma, Abdurrahman Ünsal, Merve Cömert et al.
Machines
Machine Fault Diagnosis Techniques
article

Advanced Fault Detection of Permanent Magnet Faults in Offshore Wind Turbine Generators Using Finite Element Analysis and Deep Transfer Learning

Hüseyin Tayyer Canseven, Nur Sarma, Abdurrahman Ünsal, Merve Cömert, Mustafa Ercire
article en

Abstract

As the offshore wind industry scales toward 15 MW capacity, the reliability of Direct-Drive Permanent Magnet Synchronous Generators (DD-PMSGs) becomes critical. However, real-world run-to-failure data for these massive, multi-pole machines is virtually non-existent, creating a barrier for developing effective data-driven diagnostic systems. This study proposes a high-fidelity framework for detecting permanent magnet faults in the International Energy Agency (IEA) 15 MW Reference Wind Turbine. Using Finite Element Analysis (FEA), a dataset (magnetic flux and back electromotive-force (EMF)) capturing the electromagnetic signatures of healthy and faulty states of a PMSG under varying severities is generated. To improve the power of computer vision, 1D time-series signals were transformed into 2D images. Specifically, Gramian Angular Fields (GAFs) and Recurrence Plots (RPs) were applied to magnetic flux density signals, while Markov Transition Fields (MTFs) were applied to back-EMF signals. These representations were then fused into multi-channel Red-Green-Blue (RGB) images and processed via a ResNet-18 Deep Transfer Learning model using a strictly non-overlapping, leakage-free dataset partitioning strategy. The proposed framework achieved a classification accuracy of 99.45% on noise-free data. Furthermore, robustness testing under varying levels of Additive White Gaussian Noise (AWGN) (30 dB, 40 dB, and 50 dB Signal-to-Noise Ratio (SNR)) demonstrated sustained high performance, maintaining over 90% accuracy even under severe 30 dB noise conditions. Comparative analysis proved that this multi-channel fusion significantly outperforms single-channel encoding methods, which collapse under heavy noise, validating the scalability of the framework and applicability for next-generation condition monitoring in harsh offshore environments.

MachinesVol. 14(6)
Durham University (GB), Kütahya Dumlupınar Üniversitesi (TR), Lappeenranta-Lahti University of Technology (FI)
Affordable and clean energy
Openalex Percentile: Top 7%
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.