Electronic primary thermometry: Experimental comparison of the Coulomb blockade and shot noise thermometer

Since the redefinition of the kelvin in 2019, new methods of primary thermometry have been considered to replace the currently agreed temperature scale in the very high and low temperature limits. These new methods should provide improved uncertainties and, most importantly, a more direct link to the definition of the kelvin. We present an experimental comparison of two such primary thermometers working in the mK region: the Coulomb Blockade Thermometer (CBT) and the Shot Noise Thermometer (SNT). Both thermometers measure temperature hinging only on the natural constants $k_\mathrm{B}$, and $e$. Furthermore both of them are based on electron tunneling current and, thereby, need only electrical measurements, enhancing the practicality. CBT and the SNT are inter-compared in a range of 20 mK to 235 mK. The results show that the agreement of SNT and CBT is approximately within 2.5 % in this range. Basic measurement uncertainty is analyzed and we show that uncertainty in the measurement frequency can cause significant error to temperature measurement of the SNT at low temperatures where finite frequency plays a role.

Authors

Publication Details

Journal
Physical Review Applied
Published
2026-10-16
DOI
https://doi.org/10.1103/x3y9-w82k
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electronic primary thermometry: Experimental comparison of the Coulomb blockade and shot noise thermometer

R. P. Loreto, Eemil Praks, Mika Prunnila, Yu-Cheng Chang et al.
Physical Review Applied
Scientific Measurement and Uncertainty Evaluation
article

Electronic primary thermometry: Experimental comparison of the Coulomb blockade and shot noise thermometer

R. P. Loreto, Eemil Praks, Mika Prunnila, Yu-Cheng Chang, Joonas T. Peltonen, Libin Wang, Jukka P. Pekola
article en

Abstract

Since the redefinition of the kelvin in 2019, new methods of primary thermometry have been considered to replace the currently agreed temperature scale in the very high and low temperature limits. These new methods should provide improved uncertainties and, most importantly, a more direct link to the definition of the kelvin. We present an experimental comparison of two such primary thermometers working in the mK region: the Coulomb Blockade Thermometer (CBT) and the Shot Noise Thermometer (SNT). Both thermometers measure temperature hinging only on the natural constants $k_\mathrm{B}$, and $e$. Furthermore both of them are based on electron tunneling current and, thereby, need only electrical measurements, enhancing the practicality. CBT and the SNT are inter-compared in a range of 20 mK to 235 mK. The results show that the agreement of SNT and CBT is approximately within 2.5 % in this range. Basic measurement uncertainty is analyzed and we show that uncertainty in the measurement frequency can cause significant error to temperature measurement of the SNT at low temperatures where finite frequency plays a role.

Physical Review Applied
Aalto-Yliopisto, Business Finland
Openalex Percentile: Top 62%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.