PURPOSE: The present study aimed to evaluate, in a preclinical setting, the biomechanical behavior and mechanical performance of a newly developed dental implant nut system designed to address primary stability challenges in the severely resorbed posterior maxilla. MATERIALS AND METHODS: The evaluation consisted of two complementary stages: an in vitro mechanical experiment and a finite element analysis (FEA). In the experimental phase, polyurethane jaw models simulating a severely atrophic posterior maxilla with approximately 1 mm residual bone height were used. Four groups were prepared: single implant without nut, single implant with nut, double implant without nut, and double implant with nut (n = 10 per group). Primary stability was measured using resonance frequency analysis (RFA) with an Osstell device. In the computational phase, three-dimensional finite element models were constructed from cone-beam computed tomography (CBCT) data of the same configuration to evaluate detachment forces and stress distribution within the bone-implant complex under vertical loading. RESULTS: In single-implant models, mean implant stability quotient (ISQ) values increased from 10.91 ± 7.35 to 18.27 ± 7.11 after nut application. In double-implant models, ISQ values increased from 11.13 ± 4.14 to 19.24 ± 4.24 (p < 0.05). FEA results revealed that the detachment force increased from 16.5 to 20.33 N in single-implant models and from 15 to 22.3 N in double-implant models. Compressive stresses on the bone were lower in nut-supported configurations, indicating a more favorable load distribution. CONCLUSION: The nut system was associated with increased implant primary stability and a more favorable stress distribution under the conditions of this preclinical study. These findings should be interpreted as preliminary biomechanical evidence, as no in vivo or clinical validation was performed. Therefore, this design may be considered a mechanical stabilization concept that warrants further investigation through in vivo and clinical studies.

Authors

Institutions

Publication Details

Journal
Journal of Prosthodontics
Published
2026-05-31
DOI
https://doi.org/10.1111/jopr.70169
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel dental implant nut system designed to enhance primary stability: Mechanical and finite element analysis

Alper Alkan, Burak Bal, Emrah Soylu, Mert Şahin et al.
Journal of Prosthodontics
Dental Implant Techniques and Outcomes
article

A novel dental implant nut system designed to enhance primary stability: Mechanical and finite element analysis

Alper Alkan, Burak Bal, Emrah Soylu, Mert Şahin, Ahmet Emin Demirbaş
article en

Abstract

PURPOSE: The present study aimed to evaluate, in a preclinical setting, the biomechanical behavior and mechanical performance of a newly developed dental implant nut system designed to address primary stability challenges in the severely resorbed posterior maxilla. MATERIALS AND METHODS: The evaluation consisted of two complementary stages: an in vitro mechanical experiment and a finite element analysis (FEA). In the experimental phase, polyurethane jaw models simulating a severely atrophic posterior maxilla with approximately 1 mm residual bone height were used. Four groups were prepared: single implant without nut, single implant with nut, double implant without nut, and double implant with nut (n = 10 per group). Primary stability was measured using resonance frequency analysis (RFA) with an Osstell device. In the computational phase, three-dimensional finite element models were constructed from cone-beam computed tomography (CBCT) data of the same configuration to evaluate detachment forces and stress distribution within the bone-implant complex under vertical loading. RESULTS: In single-implant models, mean implant stability quotient (ISQ) values increased from 10.91 ± 7.35 to 18.27 ± 7.11 after nut application. In double-implant models, ISQ values increased from 11.13 ± 4.14 to 19.24 ± 4.24 (p < 0.05). FEA results revealed that the detachment force increased from 16.5 to 20.33 N in single-implant models and from 15 to 22.3 N in double-implant models. Compressive stresses on the bone were lower in nut-supported configurations, indicating a more favorable load distribution. CONCLUSION: The nut system was associated with increased implant primary stability and a more favorable stress distribution under the conditions of this preclinical study. These findings should be interpreted as preliminary biomechanical evidence, as no in vivo or clinical validation was performed. Therefore, this design may be considered a mechanical stabilization concept that warrants further investigation through in vivo and clinical studies.

Journal of Prosthodontics
Turkish Society of Hematology (TR), Türkisch-Deutsche Universität (TR), Turkish Society of Cardiology (TR), Erciyes University (TR), Abdullah Gül University (TR)
Openalex Percentile: Top 4%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.