Clinical and Echocardiographic Outcomes After Implantation of the ALLEGRA Transcatheter Valve Using the Fully Repositionable IMPERIA Delivery System: One‐Year Results of the EMPIRE I Study

BACKGROUND: The EMPIRE I study assessed the early (30 days) safety and efficacy of a new fully repositionable delivery system (IMPERIA) for the commercially available ALLEGRA transcatheter aortic valve in patients with either severe native aortic stenosis or a degenerated surgical bioprosthesis. AIM: To report the final 1-year results of the EMPIRE I study. METHODS: EMPIRE I is a pre-market, prospective, multi-center, single-arm study conducted at 11 centers in 3 European countries. There were independent data safety and clinical events committees and an independent echocardiographic core laboratory. In this analysis, VARC-3 definitions of all clinical endpoints and echocardiographic parameters were employed. RESULTS: The study recruited 121 patients with severe native aortic stenosis and 16 with degenerated surgical bioprosthesis. At 1 year, the incidence of bioprosthetic valve dysfunction in the native population was 5.9%. No patients developed structural valve deterioration or endocarditis, and there were no patients with haemodynamic valve deterioration or bioprosthetic valve failure. In the valve-in-valve sub-group, 2/14 (14.3%) patients had moderate patient prosthesis mismatch at 30 days with no evidence of new bioprosthetic valve dysfunction at 1 year. In the native population, new permanent pacemaker implantation was 14.3% at 30 days and remained unchanged at 1 year. Cardiovascular mortality was 6.8% in the native population and 0% in the valve-in-valve patients. At 1-year, all-cause mortality was 10.8% (95% CI 6.4%-17.8%) in the native aortic stenosis population and 0% in the valve-in-valve patients. CONCLUSION: After 1 year of follow-up, the results of the EMPIRE 1 study show excellent haemodynamic performance, a low rate of bioprosthetic valve dysfunction, and no bioprosthetic valve failure in patients treated with the ALLEGRATM trans-catheter aortic valve implanted using the new IMPERIATM fully repositionable delivery system.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-05-31
DOI
https://doi.org/10.1002/ccd.70675
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical and Echocardiographic Outcomes After Implantation of the ALLEGRA Transcatheter Valve Using the Fully Repositionable IMPERIA Delivery System: One‐Year Results of the EMPIRE I Study

Joan Antoni Gomez, Samuel Copt, Christof Burgdorf, Keith G. Oldroyd et al.
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

Clinical and Echocardiographic Outcomes After Implantation of the ALLEGRA Transcatheter Valve Using the Fully Repositionable IMPERIA Delivery System: One‐Year Results of the EMPIRE I Study

Joan Antoni Gomez, Samuel Copt, Christof Burgdorf, Keith G. Oldroyd, Ben Ren, Anders Jönsson, Nicolas Van Mieghem, Pim Tonino, I Cruz-Gonzalez, Ernest Spitzer, Pieter Vriesendorp, Nicolas Doll, José Maria Hernândez, José Antonio Baz, Christian Frerker, Pilar Jimenez
article en

Abstract

BACKGROUND: The EMPIRE I study assessed the early (30 days) safety and efficacy of a new fully repositionable delivery system (IMPERIA) for the commercially available ALLEGRA transcatheter aortic valve in patients with either severe native aortic stenosis or a degenerated surgical bioprosthesis. AIM: To report the final 1-year results of the EMPIRE I study. METHODS: EMPIRE I is a pre-market, prospective, multi-center, single-arm study conducted at 11 centers in 3 European countries. There were independent data safety and clinical events committees and an independent echocardiographic core laboratory. In this analysis, VARC-3 definitions of all clinical endpoints and echocardiographic parameters were employed. RESULTS: The study recruited 121 patients with severe native aortic stenosis and 16 with degenerated surgical bioprosthesis. At 1 year, the incidence of bioprosthetic valve dysfunction in the native population was 5.9%. No patients developed structural valve deterioration or endocarditis, and there were no patients with haemodynamic valve deterioration or bioprosthetic valve failure. In the valve-in-valve sub-group, 2/14 (14.3%) patients had moderate patient prosthesis mismatch at 30 days with no evidence of new bioprosthetic valve dysfunction at 1 year. In the native population, new permanent pacemaker implantation was 14.3% at 30 days and remained unchanged at 1 year. Cardiovascular mortality was 6.8% in the native population and 0% in the valve-in-valve patients. At 1-year, all-cause mortality was 10.8% (95% CI 6.4%-17.8%) in the native aortic stenosis population and 0% in the valve-in-valve patients. CONCLUSION: After 1 year of follow-up, the results of the EMPIRE 1 study show excellent haemodynamic performance, a low rate of bioprosthetic valve dysfunction, and no bioprosthetic valve failure in patients treated with the ALLEGRATM trans-catheter aortic valve implanted using the new IMPERIATM fully repositionable delivery system.

Catheterization and Cardiovascular Interventions
Radboud University Nijmegen (NL), Catharina Ziekenhuis (NL), Erasmus MC (NL), Bellvitge University Hospital (ES), University Hospital Complex Of Vigo (ES), Hospital Clínico San Carlos (ES), Maastricht University (NL), Universitäres Kinderwunschzentrum Lübeck (DE), Complejo Hospitalario de Salamanca (ES), Schüchtermann-Klinik (DE), Biosensores (Spain) (ES), Klinik Lüneburger Heide (DE), Instituto de Investigación Biomédica de Salamanca (ES), Hospital Clínico Universitario Virgen de la Victoria (ES), Cardialysis (Netherlands) (NL), University of Lübeck (DE)
Good health and well-being
Openalex Percentile: Top 6%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.