Computer‐aided design of anterior guidance with a modified patient‐specific motion technique in anterior implant‐supported single crowns: A multicenter crossover trial

PURPOSE: To compare the clinical effects of computer-aided design (CAD) anterior guidance using a modified patient-specific motion (PSM) technique with the digital articulator in implant-supported crowns. MATERIALS AND METHODS: Sixty-three patients with a missing maxillary incisor scheduled for implant-supported crowns were enrolled from three hospitals. Modified PSM facilitating dynamic occlusion recording was utilized during intraoral scanning by attaching landmarks to the buccal surface of canines or first premolars. For each participant, two crowns were fabricated, differing only in the anterior guidance design. Test and control groups utilized modified PSM and a digital articulator to design anterior guidance, respectively. Crowns were delivered in a randomized sequence, while intraoral scanning and occlusal evaluation were performed. Occlusal adjustment indicators were calculated. Paired t-test and Wilcoxon signed-rank test were primarily used for statistical analysis. RESULTS: Compared with the control group, the test group showed significantly lower maximum occlusal adjustment distance (263.4 [269.6] µm vs. 362.2 [252.0] µm, p = 0.001) but similar mean and root mean square (p > 0.050). The test group demonstrated significantly reduced adjustment time, adjustment area, and lateroprotrusive interferences and higher patient (before/after adjustment) and dentist (before adjustment) satisfaction than the control group (p < 0.050). More test group crowns were selected (42 vs. 21, p = 0.008). The groups had similar occlusal clearance and occlusion scores (p > 0.050). CONCLUSIONS: Compared with a digital articulator, CAD anterior guidance using modified PSM for implant-supported single crowns reduces maximum adjustment distance, adjustment time and area, and occlusal interferences, and improves patient/dentist satisfaction.

Authors

Institutions

Publication Details

Journal
Journal of Prosthodontics
Published
2026-05-31
DOI
https://doi.org/10.1111/jopr.70164
Primary Topic
Temporomandibular Joint Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computer‐aided design of anterior guidance with a modified patient‐specific motion technique in anterior implant‐supported single crowns: A multicenter crossover trial

Bin Luo, Shimin Wang, Liang Shao, Qian Ding et al.
Journal of Prosthodontics
Temporomandibular Joint Disorders
article

Computer‐aided design of anterior guidance with a modified patient‐specific motion technique in anterior implant‐supported single crowns: A multicenter crossover trial

Bin Luo, Shimin Wang, Liang Shao, Qian Ding, Qingsong Jiang, Lei Zhang, Qingqing Li, Rui Zhang
article en

Abstract

PURPOSE: To compare the clinical effects of computer-aided design (CAD) anterior guidance using a modified patient-specific motion (PSM) technique with the digital articulator in implant-supported crowns. MATERIALS AND METHODS: Sixty-three patients with a missing maxillary incisor scheduled for implant-supported crowns were enrolled from three hospitals. Modified PSM facilitating dynamic occlusion recording was utilized during intraoral scanning by attaching landmarks to the buccal surface of canines or first premolars. For each participant, two crowns were fabricated, differing only in the anterior guidance design. Test and control groups utilized modified PSM and a digital articulator to design anterior guidance, respectively. Crowns were delivered in a randomized sequence, while intraoral scanning and occlusal evaluation were performed. Occlusal adjustment indicators were calculated. Paired t-test and Wilcoxon signed-rank test were primarily used for statistical analysis. RESULTS: Compared with the control group, the test group showed significantly lower maximum occlusal adjustment distance (263.4 [269.6] µm vs. 362.2 [252.0] µm, p = 0.001) but similar mean and root mean square (p > 0.050). The test group demonstrated significantly reduced adjustment time, adjustment area, and lateroprotrusive interferences and higher patient (before/after adjustment) and dentist (before adjustment) satisfaction than the control group (p < 0.050). More test group crowns were selected (42 vs. 21, p = 0.008). The groups had similar occlusal clearance and occlusion scores (p > 0.050). CONCLUSIONS: Compared with a digital articulator, CAD anterior guidance using modified PSM for implant-supported single crowns reduces maximum adjustment distance, adjustment time and area, and occlusal interferences, and improves patient/dentist satisfaction.

Journal of Prosthodontics
King University (US), Peking University (CN), Peking University People's Hospital (CN), Peking University Shenzhen Hospital (CN), Stomatology Hospital (CN)
Openalex Percentile: Top 4%
Temporomandibular Joint Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.