Suppression Method of Sub/Super-Synchronous Oscillation in Direct-Drive Wind Farms Based on a Hybrid GFL-GFM Control Configuration

Currently, grid-following (GFL) control is widely adopted in direct-drive wind farms. Its external impedance characteristic exhibits negative resistance and capacitive reactance, frequently inducing sub/super-synchronous oscillations in the direct-drive wind farm and weak grid interactive system. The positive resistance characteristic of grid-forming (GFM) control can, to a certain extent, improve the impedance characteristic of wind farms and enhance the system stability margin. However, the influence of the proportion and deployment location of GFM control within a wind farm on the mitigation of sub/super-synchronous oscillations merits further exploration. First, this paper establishes the sequence impedance models for both GFL and GFM control, analyzes the underlying causes of system oscillations from an impedance perspective, and proposes a method for calculating the stability margin of a grid-connected direct-drive wind farm system that comprehensively accounts for the generalized short-circuit ratio, the critical short-circuit ratio of the equipment, and the steady-state operational constraints of the system. Subsequently, the mitigation effects of the connection location and capacity proportion of GFM wind turbines on sub/super-synchronous oscillations are quantitatively assessed, yielding feasible ranges of the short-circuit ratio under various operating conditions that ensure stable operation of the direct-drive wind farm. The system stability is further examined via Nyquist curve analysis. Finally, the effectiveness of the proposed method is validated by electromagnetic transient simulations in MATLAB/Simulink.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-05-31
DOI
https://doi.org/10.3390/en19112661
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Suppression Method of Sub/Super-Synchronous Oscillation in Direct-Drive Wind Farms Based on a Hybrid GFL-GFM Control Configuration

Kun Wang, Jiang Li
Energies
Microgrid Control and Optimization
article

Suppression Method of Sub/Super-Synchronous Oscillation in Direct-Drive Wind Farms Based on a Hybrid GFL-GFM Control Configuration

Kun Wang, Jiang Li
article en

Abstract

Currently, grid-following (GFL) control is widely adopted in direct-drive wind farms. Its external impedance characteristic exhibits negative resistance and capacitive reactance, frequently inducing sub/super-synchronous oscillations in the direct-drive wind farm and weak grid interactive system. The positive resistance characteristic of grid-forming (GFM) control can, to a certain extent, improve the impedance characteristic of wind farms and enhance the system stability margin. However, the influence of the proportion and deployment location of GFM control within a wind farm on the mitigation of sub/super-synchronous oscillations merits further exploration. First, this paper establishes the sequence impedance models for both GFL and GFM control, analyzes the underlying causes of system oscillations from an impedance perspective, and proposes a method for calculating the stability margin of a grid-connected direct-drive wind farm system that comprehensively accounts for the generalized short-circuit ratio, the critical short-circuit ratio of the equipment, and the steady-state operational constraints of the system. Subsequently, the mitigation effects of the connection location and capacity proportion of GFM wind turbines on sub/super-synchronous oscillations are quantitatively assessed, yielding feasible ranges of the short-circuit ratio under various operating conditions that ensure stable operation of the direct-drive wind farm. The system stability is further examined via Nyquist curve analysis. Finally, the effectiveness of the proposed method is validated by electromagnetic transient simulations in MATLAB/Simulink.

EnergiesVol. 19(11)
Shanghai University of Electric Power (CN)
Affordable and clean energy
Openalex Percentile: Top 6%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.