Strength resistance factors calibration for shear in FRP-reinforced concrete beams

The reduction factors currently used in fiber-reinforced polymer (FRP) reinforced concrete design codes are largely derived from those developed for steel-reinforced concrete, leading to inconsistent safety levels across different material systems. To address this issue, specifically for FRP-reinforced concrete (FRP-RC) beams subjected to shear, this study compiles a comprehensive database of 122 experimental results from FRP-RC beams that failed in shear. A reliability analysis was conducted to evaluate the safety performance of two widely used design standards: ACI 440.1R-15 and CAN/CSA S806-12. The goal is to assess the adequacy of their current reduction factors and propose revised values that achieve a consistent target reliability level across both codes. The analysis shows that the reduction factor specified in ACI 440.1R-15 (0.75) yields a reliability index of 3.5, which aligns with the target level recommended by ASCE 7-22. In contrast, the CAN/CSA S806-12 design equation, which uses a reduction factor of 0.65 for concrete, slightly underperforms in terms of reliability. A more conservative reduction factor of 0.60 is therefore proposed to bring its safety level in line with that of ACI 440.1R-15, ensuring consistency between the two codes. Unlike prior studies that relied on approximate methods (FORM/FOSM) or focused on modified equations, this work employs Monte Carlo Simulation with 1 × 107 iterations on the unmodified code provisions across multiple load combinations (dead, live, wind, and snow), providing a more comprehensive and robust reliability assessment framework.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2026-05-31
DOI
https://doi.org/10.1007/s42452-026-08875-9
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Strength resistance factors calibration for shear in FRP-reinforced concrete beams

Firass Mohamad, Ahed Habib, Moussa Leblouba, Maan Habib et al.
Discover Applied Sciences
Structural Behavior of Reinforced Concrete
article

Strength resistance factors calibration for shear in FRP-reinforced concrete beams

Firass Mohamad, Ahed Habib, Moussa Leblouba, Maan Habib, Samer Barakat, Aroob Alateyat
article en

Abstract

The reduction factors currently used in fiber-reinforced polymer (FRP) reinforced concrete design codes are largely derived from those developed for steel-reinforced concrete, leading to inconsistent safety levels across different material systems. To address this issue, specifically for FRP-reinforced concrete (FRP-RC) beams subjected to shear, this study compiles a comprehensive database of 122 experimental results from FRP-RC beams that failed in shear. A reliability analysis was conducted to evaluate the safety performance of two widely used design standards: ACI 440.1R-15 and CAN/CSA S806-12. The goal is to assess the adequacy of their current reduction factors and propose revised values that achieve a consistent target reliability level across both codes. The analysis shows that the reduction factor specified in ACI 440.1R-15 (0.75) yields a reliability index of 3.5, which aligns with the target level recommended by ASCE 7-22. In contrast, the CAN/CSA S806-12 design equation, which uses a reduction factor of 0.65 for concrete, slightly underperforms in terms of reliability. A more conservative reduction factor of 0.60 is therefore proposed to bring its safety level in line with that of ACI 440.1R-15, ensuring consistency between the two codes. Unlike prior studies that relied on approximate methods (FORM/FOSM) or focused on modified equations, this work employs Monte Carlo Simulation with 1 × 107 iterations on the unmodified code provisions across multiple load combinations (dead, live, wind, and snow), providing a more comprehensive and robust reliability assessment framework.

Discover Applied Sciences
University of Sharjah (AE), Fahd bin Sultan University (SA), Syrian Private University (SY)
Sustainable cities and communities
Openalex Percentile: Top 8%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.