Electrical impedance tomography-derived flow index during spontaneous breathing trial stratifies the risk of reintubation within 48 h after extubation

BACKGROUND: Spontaneous breathing trial (SBT) is the standard test of readiness for liberation from invasive mechanical ventilation, but some patients who successfully complete SBT still experience early post-extubation failure. Inspiratory effort during SBT has emerged as an important physiological determinant of weaning tolerance and extubation outcome because it reflects the balance between ventilatory load and respiratory muscle capacity, yet its assessment often requires airway occlusions, dedicated ventilator algorithms, or intermittent measurements. We therefore evaluated whether an electrical impedance tomography (EIT)-derived flow index (EFI) measured during SBT was associated with SBT outcome and with reintubation within 48 h after extubation. METHODS: In this prospective multicenter observational study, mechanically ventilated adults receiving invasive ventilation for at least 48 h underwent a standardized 30-min pressure support SBT with continuous EIT monitoring. EFI was calculated breath by breath from EIT-derived inspiratory flow-time profiles. The primary endpoint was SBT outcome. A prespecified key secondary endpoint was reintubation within 48 h after planned extubation among patients who successfully completed the SBT and underwent extubation according to routine care. EFI discrimination for SBT failure was assessed using receiver operating characteristic analysis. For the post-extubation analysis, 48-h freedom from reintubation was evaluated using Kaplan-Meier analysis and Cox proportional hazards models. RESULTS: A total of 150 patients were enrolled, of whom 107 successfully completed the SBT and underwent planned extubation. EFI showed excellent discrimination for the primary endpoint of SBT outcome (AUC 0.980) and provided early physiological warning of evolving SBT intolerance. Reintubation within 48 h occurred in 7 of 107 extubated patients. Using the EFI threshold of 1.333 derived from the primary endpoint analysis, patients with EFI < 1.333 had significantly lower 48-h freedom from reintubation than those with EFI ≥ 1.333, and all reintubation events occurred in the EFI < 1.333 group. In univariable Cox analyses, EFI, RSBI, MIP, and P0.1 were each associated with reintubation within 48 h after extubation. Because of severe multicollinearity among these indices and the very small number of events, a combined multivariable model was not pursued. CONCLUSIONS: EFI measured during SBT was strongly associated with SBT outcome and showed an exploratory association with reintubation within 48 h after extubation. Beyond identifying SBT intolerance, EFI may help identify patients with residual physiological vulnerability after a successful SBT; however, this secondary finding requires cautious interpretation and external validation. TRIAL REGISTRATION: ClinicalTrials.gov NCT06876792. Registered on March 10, 2025.

Authors

Institutions

Publication Details

Journal
Critical Care
Published
2026-05-31
DOI
https://doi.org/10.1186/s13054-026-06098-3
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical impedance tomography-derived flow index during spontaneous breathing trial stratifies the risk of reintubation within 48 h after extubation

Donghuang Hong, Jianmin Wu, J S Liu, R U I Y A N Zhang et al.
Critical Care
Respiratory Support and Mechanisms
article

Electrical impedance tomography-derived flow index during spontaneous breathing trial stratifies the risk of reintubation within 48 h after extubation

Donghuang Hong, Jianmin Wu, J S Liu, R U I Y A N Zhang, Y Long, D Wu, Ruoming Tan, Jing Xu, Hongping Qu, Huaiwu He, Zhanqi Zhao
article en

Abstract

BACKGROUND: Spontaneous breathing trial (SBT) is the standard test of readiness for liberation from invasive mechanical ventilation, but some patients who successfully complete SBT still experience early post-extubation failure. Inspiratory effort during SBT has emerged as an important physiological determinant of weaning tolerance and extubation outcome because it reflects the balance between ventilatory load and respiratory muscle capacity, yet its assessment often requires airway occlusions, dedicated ventilator algorithms, or intermittent measurements. We therefore evaluated whether an electrical impedance tomography (EIT)-derived flow index (EFI) measured during SBT was associated with SBT outcome and with reintubation within 48 h after extubation. METHODS: In this prospective multicenter observational study, mechanically ventilated adults receiving invasive ventilation for at least 48 h underwent a standardized 30-min pressure support SBT with continuous EIT monitoring. EFI was calculated breath by breath from EIT-derived inspiratory flow-time profiles. The primary endpoint was SBT outcome. A prespecified key secondary endpoint was reintubation within 48 h after planned extubation among patients who successfully completed the SBT and underwent extubation according to routine care. EFI discrimination for SBT failure was assessed using receiver operating characteristic analysis. For the post-extubation analysis, 48-h freedom from reintubation was evaluated using Kaplan-Meier analysis and Cox proportional hazards models. RESULTS: A total of 150 patients were enrolled, of whom 107 successfully completed the SBT and underwent planned extubation. EFI showed excellent discrimination for the primary endpoint of SBT outcome (AUC 0.980) and provided early physiological warning of evolving SBT intolerance. Reintubation within 48 h occurred in 7 of 107 extubated patients. Using the EFI threshold of 1.333 derived from the primary endpoint analysis, patients with EFI < 1.333 had significantly lower 48-h freedom from reintubation than those with EFI ≥ 1.333, and all reintubation events occurred in the EFI < 1.333 group. In univariable Cox analyses, EFI, RSBI, MIP, and P0.1 were each associated with reintubation within 48 h after extubation. Because of severe multicollinearity among these indices and the very small number of events, a combined multivariable model was not pursued. CONCLUSIONS: EFI measured during SBT was strongly associated with SBT outcome and showed an exploratory association with reintubation within 48 h after extubation. Beyond identifying SBT intolerance, EFI may help identify patients with residual physiological vulnerability after a successful SBT; however, this secondary finding requires cautious interpretation and external validation. TRIAL REGISTRATION: ClinicalTrials.gov NCT06876792. Registered on March 10, 2025.

Critical Care
Fujian Medical University (CN), Shanghai Jiao Tong University (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Ruijin Hospital (CN), Fujian Provincial Hospital (CN), Guangzhou Medical University (CN)
Shanghai Municipal Health Commission
Peace, Justice and strong institutions, Reduced inequalities
Openalex Percentile: Top 6%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.