Value and Sustainability of Semi-reusable Patch Pump Therapy in Routine Care: A Prospective Multicentre Study

BACKGROUND: Patch insulin pumps are often treated as a single class, although fully disposable and semi-reusable designs differ in cost and waste. We evaluated real-world clinical, pharmacoeconomic, and environmental outcomes of a semi-reusable tubeless insulin pump (Microtech Equil™, referred as SR-TIP). METHODS: Prospective, multicentre, open-label real-world study in adults with type 1 or type 2 diabetes transitioning from continuous subcutaneous insulin infusion (CSII) or multiple daily injections (MDI). Follow-up was 3 months. Primary endpoints were HbA1c non-inferiority and change in hypoglycaemic event frequency. Secondary endpoints included safety, device deficiencies, patient-reported outcomes (Diabetes Treatment Satisfaction Questionnaire, Device Assessment Questionnaire), monthly disposable treatment costs, and waste based on disposable component counts and material composition. RESULTS: Ninety-seven participants completed follow-up (CSII n = 79; MDI n = 18). HbA1c changes met non-inferiority criteria in both groups. Hypoglycaemic events decreased by 45% in CSII users and 86% in MDI users. Device-related adverse events were infrequent and mainly mild. Among participants previously using fully disposable tubeless pumps, mean monthly disposable treatment costs decreased by €108.6 (p < 0.001). The semi-reusable architecture eliminated routine disposal of batteries/electronic components and reduced overall waste. CONCLUSIONS: In routine care, a semi-reusable tubeless pump maintained glycaemic control while reducing hypoglycaemia and disposable costs versus fully disposable patch pumps, with measurable reductions in electronic waste. These data support value-based, sustainable diabetes technology adoption.

Authors

Institutions

Publication Details

Journal
Journal of Diabetes Science and Technology
Published
2026-05-31
DOI
https://doi.org/10.1177/19322968261449828
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Value and Sustainability of Semi-reusable Patch Pump Therapy in Routine Care: A Prospective Multicentre Study

Christian Taucher, A Pfützner, Winfried Keuthage, Julia Jantz et al.
Journal of Diabetes Science and Technology
Diabetes Management and Research
article

Value and Sustainability of Semi-reusable Patch Pump Therapy in Routine Care: A Prospective Multicentre Study

Christian Taucher, A Pfützner, Winfried Keuthage, Julia Jantz, Babette Lorra, Silvia Basta, Julia Mader, Selahaddin Inan, Hakan Inan, Sebnem Harput Doner, Norbert Hermanns, Hüseyin Uysal, Novihoho Abra Maudline, Thomas Haak, Weiwei Zhu
article en

Abstract

BACKGROUND: Patch insulin pumps are often treated as a single class, although fully disposable and semi-reusable designs differ in cost and waste. We evaluated real-world clinical, pharmacoeconomic, and environmental outcomes of a semi-reusable tubeless insulin pump (Microtech Equil™, referred as SR-TIP). METHODS: Prospective, multicentre, open-label real-world study in adults with type 1 or type 2 diabetes transitioning from continuous subcutaneous insulin infusion (CSII) or multiple daily injections (MDI). Follow-up was 3 months. Primary endpoints were HbA1c non-inferiority and change in hypoglycaemic event frequency. Secondary endpoints included safety, device deficiencies, patient-reported outcomes (Diabetes Treatment Satisfaction Questionnaire, Device Assessment Questionnaire), monthly disposable treatment costs, and waste based on disposable component counts and material composition. RESULTS: Ninety-seven participants completed follow-up (CSII n = 79; MDI n = 18). HbA1c changes met non-inferiority criteria in both groups. Hypoglycaemic events decreased by 45% in CSII users and 86% in MDI users. Device-related adverse events were infrequent and mainly mild. Among participants previously using fully disposable tubeless pumps, mean monthly disposable treatment costs decreased by €108.6 (p < 0.001). The semi-reusable architecture eliminated routine disposal of batteries/electronic components and reduced overall waste. CONCLUSIONS: In routine care, a semi-reusable tubeless pump maintained glycaemic control while reducing hypoglycaemia and disposable costs versus fully disposable patch pumps, with measurable reductions in electronic waste. These data support value-based, sustainable diabetes technology adoption.

Journal of Diabetes Science and Technology
TH Bingen University of Applied Sciences (DE), Medical University of Graz (AT), German Diabetes Center Mergentheim (DE), Diabetes Australia (AU), Toptica Photonics (Germany) (DE), Institut Supérieur de Formation à Distance (GN), Diabetes-Akademie (DE), Cascade Microtech (United States) (US)
Openalex Percentile: Top 7%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.