Residual Water Suppression in MRS Using HLSVD With Automatic Component Selection Strategy

Residual water signals in magnetic resonance spectroscopy (MRS) can distort baselines and complicate metabolite quantification, particularly in regions with poor field homogeneity and in MRSI. The Hankel Lanczos singular value decomposition (HLSVD) method is widely used for Residual water removal, but its performance depends on the number of components selected. This study proposes an automatic approach that combines HLSVD with the residual water to metabolite variance ratio (RWVR) for component selection. The RWVR, defined as the variance of spectral fluctuations in the water region (4.2-5.2 ppm) normalized to the metabolite region (0.5-4.0 ppm). HLSVD was applied using component numbers between 10 and 32, and the configuration yielding the minimal RWVR was chosen as optimal. The method was evaluated on single voxel spectroscopy (SVS) data from four brain regions and on MRSI datasets acquired at 3 T. The Residual Water Index, defined as the variance ratio before and after RW removal, was used to assess suppression performance. Optimal component numbers were more frequently found in the range of 22-32, consistent with prior reports. With the identified component numbers, acceptable spectra across both SVS and MRSI can be produced. While multiple component numbers often yielded similar outcomes, some choices led to unacceptable spectra with baseline distortions. RWVR provided an effective indicator for avoiding such outcomes. Residual water index values were generally low, confirming effective suppression, though a small subset of cases exhibited irregular residual water lineshapes and higher RWVR. By evaluating multiple component numbers and choosing the configuration that minimizes RWVR, the proposed method avoids manual tuning and ensures acceptable suppression across both SVS and MRSI data. This approach offers a practical solution for large-scale studies where consistent and reliable residual water removal is essential.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-05-31
DOI
https://doi.org/10.1002/nbm.70325
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Residual Water Suppression in MRS Using HLSVD With Automatic Component Selection Strategy

Shang‐Yueh Tsai, Zheng‐De Hong, Yi‐Ru Lin
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

Residual Water Suppression in MRS Using HLSVD With Automatic Component Selection Strategy

Shang‐Yueh Tsai, Zheng‐De Hong, Yi‐Ru Lin
article en

Abstract

Residual water signals in magnetic resonance spectroscopy (MRS) can distort baselines and complicate metabolite quantification, particularly in regions with poor field homogeneity and in MRSI. The Hankel Lanczos singular value decomposition (HLSVD) method is widely used for Residual water removal, but its performance depends on the number of components selected. This study proposes an automatic approach that combines HLSVD with the residual water to metabolite variance ratio (RWVR) for component selection. The RWVR, defined as the variance of spectral fluctuations in the water region (4.2-5.2 ppm) normalized to the metabolite region (0.5-4.0 ppm). HLSVD was applied using component numbers between 10 and 32, and the configuration yielding the minimal RWVR was chosen as optimal. The method was evaluated on single voxel spectroscopy (SVS) data from four brain regions and on MRSI datasets acquired at 3 T. The Residual Water Index, defined as the variance ratio before and after RW removal, was used to assess suppression performance. Optimal component numbers were more frequently found in the range of 22-32, consistent with prior reports. With the identified component numbers, acceptable spectra across both SVS and MRSI can be produced. While multiple component numbers often yielded similar outcomes, some choices led to unacceptable spectra with baseline distortions. RWVR provided an effective indicator for avoiding such outcomes. Residual water index values were generally low, confirming effective suppression, though a small subset of cases exhibited irregular residual water lineshapes and higher RWVR. By evaluating multiple component numbers and choosing the configuration that minimizes RWVR, the proposed method avoids manual tuning and ensures acceptable suppression across both SVS and MRSI data. This approach offers a practical solution for large-scale studies where consistent and reliable residual water removal is essential.

NMR in BiomedicineVol. 39(7)
National Taiwan University of Science and Technology (TW), National Chengchi University (TW)
National Science and Technology Council
Clean water and sanitation
Openalex Percentile: Top 5%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.