A Novel Two‐Stage Cluster‐Based Robust Standard Deviation Control Chart

ABSTRACT This study proposes a robust standard deviation estimator for Phase I control charts. The method uses a two‐stage cluster‐based outlier screening mechanism that combines K‐means clustering with silhouette coefficient analysis. The first stage screens at the group level, and the second stage screens individual observations. Both stages include mechanisms to protect extreme values. We evaluate the method through Monte Carlo simulations under four contamination scenarios: symmetric variance, asymmetric variance, localized variance, and diffuse mean disturbances. Results show that and perform best in Phase I parameter estimation. These variants also show strong robustness in Phase II control chart implementation. The proposed control charts maintain average run length (ARL) values close to nominal specifications under contamination. They show superior detection capabilities for process shifts compared to established robust estimators.

Authors

Institutions

Publication Details

Journal
Quality and Reliability Engineering International
Published
2026-05-31
DOI
https://doi.org/10.1002/qre.70278
Primary Topic
Advanced Statistical Process Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Two‐Stage Cluster‐Based Robust Standard Deviation Control Chart

Shih‐Chou Kao
Quality and Reliability Engineering International
Advanced Statistical Process Monitoring
article

A Novel Two‐Stage Cluster‐Based Robust Standard Deviation Control Chart

Shih‐Chou Kao
article en

Abstract

ABSTRACT This study proposes a robust standard deviation estimator for Phase I control charts. The method uses a two‐stage cluster‐based outlier screening mechanism that combines K‐means clustering with silhouette coefficient analysis. The first stage screens at the group level, and the second stage screens individual observations. Both stages include mechanisms to protect extreme values. We evaluate the method through Monte Carlo simulations under four contamination scenarios: symmetric variance, asymmetric variance, localized variance, and diffuse mean disturbances. Results show that and perform best in Phase I parameter estimation. These variants also show strong robustness in Phase II control chart implementation. The proposed control charts maintain average run length (ARL) values close to nominal specifications under contamination. They show superior detection capabilities for process shifts compared to established robust estimators.

Quality and Reliability Engineering International
National United University (TW)
Openalex Percentile: Top 6%
Advanced Statistical Process Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.