Multiple‐ <scp>TE</scp> Based Blood–Brain‐Barrier Water Exchange Time Measurement Using a <scp>TE</scp> ‐Resolved <scp>3D TSE</scp> Stack‐Of‐Spirals Readout

ABSTRACT Purpose To develop a slice‐wise blurring‐free and densely sampled TE‐resolved multiple‐TE (mTE) ASL sequence (TASL) for measuring blood–brain barrier (BBB) water exchange time. Methods A 3D TSE spiral‐readout pCASL sequence was modified to enable TE‐resolved acquisition. Signals at mTEs from a single kz partition were acquired within a single shot, and the acquisition was repeated until all required kz partitions were covered. In vivo experiments were conducted on healthy volunteers using both a conventional pCASL sequence and the proposed TASL sequence. Signal intensity modulation, perfusion SNR, and quantitative parameters including cerebral blood flow (CBF), arterial transit time (ATT), intravoxel transit time ( ITT ), and water exchange time ( T exch ) were evaluated. Test–retest scans were conducted to assess reproducibility. Results Compared with the conventional mTE acquisition, TASL eliminates T 2 decay‐induced slice‐wise intensity modulation and blurring, yielding higher whole‐brain perfusion SNR across all TEs and PLDs. Estimates of CBF and ATT showed negligible differences between the two methods (both &lt; 1%), whereas mean T exch and ITT values were 18.2% and 9.05% higher, respectively, with TASL. Bland–Altman analysis showed minimal bias, with 95% of differences within the limits of agreement (mean±1.96 SD). The inter‐session ICC and wsCV of CBF, ATT, T exch , and ITT in gray matter are 0.86% and 8.38%, 0.96% and 1.98%, 0.93% and 4.04%, and 0.95% and 4.32%, respectively. Conclusion TASL eliminates signal intensity modulation and blurring artifacts while providing densely sampled TE for parametric fitting. It may be a valuable tool for accurate and reliable quantification of cerebral perfusion and BBB permeability.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-05-30
DOI
https://doi.org/10.1002/mrm.70450
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple‐ TE Based Blood–Brain‐Barrier Water Exchange Time Measurement Using a TE ‐Resolved 3D TSE Stack‐Of‐Spirals Readout

Z Wang, Lucas Lemos Franco, Amnah Mahroo, Marta Vidorreta Díaz de Cerio et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Multiple‐ TE Based Blood–Brain‐Barrier Water Exchange Time Measurement Using a TE ‐Resolved 3D TSE Stack‐Of‐Spirals Readout

Z Wang, Lucas Lemos Franco, Amnah Mahroo, Marta Vidorreta Díaz de Cerio, María Asunción Fernández Seara, Manuel Taso, Yulin Chang, Xiao Liang, John A. Detre, Yiran Li, Matthias Günther, Bo Li
article en

Abstract

ABSTRACT Purpose To develop a slice‐wise blurring‐free and densely sampled TE‐resolved multiple‐TE (mTE) ASL sequence (TASL) for measuring blood–brain barrier (BBB) water exchange time. Methods A 3D TSE spiral‐readout pCASL sequence was modified to enable TE‐resolved acquisition. Signals at mTEs from a single kz partition were acquired within a single shot, and the acquisition was repeated until all required kz partitions were covered. In vivo experiments were conducted on healthy volunteers using both a conventional pCASL sequence and the proposed TASL sequence. Signal intensity modulation, perfusion SNR, and quantitative parameters including cerebral blood flow (CBF), arterial transit time (ATT), intravoxel transit time ( ITT ), and water exchange time ( T exch ) were evaluated. Test–retest scans were conducted to assess reproducibility. Results Compared with the conventional mTE acquisition, TASL eliminates T 2 decay‐induced slice‐wise intensity modulation and blurring, yielding higher whole‐brain perfusion SNR across all TEs and PLDs. Estimates of CBF and ATT showed negligible differences between the two methods (both &lt; 1%), whereas mean T exch and ITT values were 18.2% and 9.05% higher, respectively, with TASL. Bland–Altman analysis showed minimal bias, with 95% of differences within the limits of agreement (mean±1.96 SD). The inter‐session ICC and wsCV of CBF, ATT, T exch , and ITT in gray matter are 0.86% and 8.38%, 0.96% and 1.98%, 0.93% and 4.04%, and 0.95% and 4.32%, respectively. Conclusion TASL eliminates signal intensity modulation and blurring artifacts while providing densely sampled TE for parametric fitting. It may be a valuable tool for accurate and reliable quantification of cerebral perfusion and BBB permeability.

Magnetic Resonance in Medicine
University of Maryland, Baltimore (US), University of Maryland Medical Center (US), University Health Network (CA), Gobierno de Navarra (ES), Fraunhofer Institute for Digital Medicine (DE), Ontario Brain Institute (CA), Siemens (Spain) (ES), University of Baltimore (US), University of Pennsylvania (US), Universidad de Navarra (ES)
National Institute on Aging, National Institute of Biomedical Imaging and Bioengineering
Clean water and sanitation
Openalex Percentile: Top 5%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.