Wideband black- and bright-blood late gadolinium enhancement imaging in patients with implantable cardiac devices at 1.5T for improved visualization and localization of myocardial injury

Abstract Aims Late gadolinium enhancement (LGE) imaging in patients with implantable cardiac devices is often degraded by device-related artefacts. Wideband phase-sensitive inversion-recovery (PSIR) mitigates these artefacts but suffers from low scar-blood contrast, limiting detection of subendocardial and small focal scars. Therefore, a novel wideband SPOT sequence combining co-registered wideband black- and bright-blood LGE to improve scar-blood contrast and localization, with wideband inversion recovery and wideband T2 preparation for artefact reduction, was implemented at 1.5T. Methods and Results Wideband SPOT was compared with wideband PSIR, conventional PSIR and conventional SPOT in an animal and 18 patients with devices and known myocardial lesions. Patient analyses included qualitative assessment of image quality, artefact severity, diagnostic confidence, and LGE segment detection; quantitative measurements of left ventricular (LV) volume, scar volume, and scar size; agreement analysis between wideband SPOT and wideband PSIR; and reproducibility analysis. In the animal, wideband SPOT reduced device-related artefacts and enabled accurate scar localization consistent with histology. In patients, wideband SPOT and wideband PSIR yielded similar image and artefact reduction (P>0.05), but wideband SPOT reduced diagnostic uncertainty by 24% (P=0.080). Inter-observer agreement for qualitative scores was moderate to good (ICC 0.54–0.83, P<0.001). Quantitative LV and scar measurements demonstrated excellent correlation (r>0.9, P<0.01) and good-to-excellent reproducibility (ICC 0.85–0.98, P<0.001) between techniques. Conclusion Compared with wideband PSIR, wideband SPOT showed a trend toward enhanced scar detection, identifying additional scarred segments while maintaining similar overall scar burden. It also improved inter-observer agreement, preserved anatomical reference, and reduced device artefacts, which may improve diagnostic confidence and risk stratification.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Imaging Methods and Practice
Published
2026-05-29
DOI
https://doi.org/10.1093/ehjimp/qyag102
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wideband black- and bright-blood late gadolinium enhancement imaging in patients with implantable cardiac devices at 1.5T for improved visualization and localization of myocardial injury

Pauline Gut, Guido Caluori, Panagiotis Antiochos, Ambra Masi et al.
European Heart Journal - Imaging Methods and Practice
Cardiac Imaging and Diagnostics
article

Wideband black- and bright-blood late gadolinium enhancement imaging in patients with implantable cardiac devices at 1.5T for improved visualization and localization of myocardial injury

Pauline Gut, Guido Caluori, Panagiotis Antiochos, Ambra Masi, Aurélien Bustin, Baptiste Durand, F Sacher, Hubert Cochet, Juerg Schwitter, Konstantinos Vlachos, Matthias Stuber, Pierre Jaïs
article en

Abstract

Abstract Aims Late gadolinium enhancement (LGE) imaging in patients with implantable cardiac devices is often degraded by device-related artefacts. Wideband phase-sensitive inversion-recovery (PSIR) mitigates these artefacts but suffers from low scar-blood contrast, limiting detection of subendocardial and small focal scars. Therefore, a novel wideband SPOT sequence combining co-registered wideband black- and bright-blood LGE to improve scar-blood contrast and localization, with wideband inversion recovery and wideband T2 preparation for artefact reduction, was implemented at 1.5T. Methods and Results Wideband SPOT was compared with wideband PSIR, conventional PSIR and conventional SPOT in an animal and 18 patients with devices and known myocardial lesions. Patient analyses included qualitative assessment of image quality, artefact severity, diagnostic confidence, and LGE segment detection; quantitative measurements of left ventricular (LV) volume, scar volume, and scar size; agreement analysis between wideband SPOT and wideband PSIR; and reproducibility analysis. In the animal, wideband SPOT reduced device-related artefacts and enabled accurate scar localization consistent with histology. In patients, wideband SPOT and wideband PSIR yielded similar image and artefact reduction (P>0.05), but wideband SPOT reduced diagnostic uncertainty by 24% (P=0.080). Inter-observer agreement for qualitative scores was moderate to good (ICC 0.54–0.83, P<0.001). Quantitative LV and scar measurements demonstrated excellent correlation (r>0.9, P<0.01) and good-to-excellent reproducibility (ICC 0.85–0.98, P<0.001) between techniques. Conclusion Compared with wideband PSIR, wideband SPOT showed a trend toward enhanced scar detection, identifying additional scarred segments while maintaining similar overall scar burden. It also improved inter-observer agreement, preserved anatomical reference, and reduced device artefacts, which may improve diagnostic confidence and risk stratification.

European Heart Journal - Imaging Methods and Practice
Université de Bordeaux (FR), Inserm (FR), Electrophysiology and Heart Modeling Institute (FR), Hôpital Cardiologique du Haut-Lévêque (FR), Centre d'Imagerie BioMedicale (CH), University of Lausanne (CH)
Openalex Percentile: Top 5%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.