Experimental emulation of charge air cooler temperature and pressure on an engine dynamometer for air–fuel ratio optimization and pulsation reduction

This study presents an experimental investigation aimed at addressing charge air cooler (CAC) delta temperature variation and air pulsation issues encountered during final vehicle calibration on engine dynamometers. Conventional calibration setups typically employ customized water-cooled CAC systems, which often fail to replicate actual vehicle conditions, leading to discrepancies in pressure, temperature, and air-fuel ratio (AFR). To overcome this limitation, a novel air-to-air (A2A) CAC configuration incorporating a dynamically controlled airflow system using a variable frequency drive (VFD) and a closed-loop PID controller was implemented on the engine dynamometer. The proposed setup enables accurate emulation of vehicle charge air temperature and pressure conditions under both stationary and transient operating modes. Experimental results demonstrate a significant reduction in pressure drop from 10 kPa to 1.2 kPa and improved temperature control from 49 °C to 39 °C, resulting in an efficiency improvement of approximately 6-8% compared to conventional water-cooled systems. The optimized CAC performance contributes to improved air density, stable AFR, reduced air pulsation (pumping loss), and enhanced overall engine efficiency. The findings confirm that the proposed methodology effectively replicates real vehicle conditions on the dynamometer, thereby minimizing iterative calibration efforts, reducing development time and cost, and improving reliability in OEM calibration processes.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-30
DOI
https://doi.org/10.1038/s41598-026-53715-w
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental emulation of charge air cooler temperature and pressure on an engine dynamometer for air–fuel ratio optimization and pulsation reduction

Naseem Khayum, P. M. G. Bashir Asdaque, Hari Prasadarao Pydi, Viswanathan Rajan et al.
Scientific Reports
Aerodynamics and Fluid Dynamics Research
article

Experimental emulation of charge air cooler temperature and pressure on an engine dynamometer for air–fuel ratio optimization and pulsation reduction

Naseem Khayum, P. M. G. Bashir Asdaque, Hari Prasadarao Pydi, Viswanathan Rajan, Syed Suraya, T. Srinivas Rao, Rajendra Kumar Jagadeesh
article en

Abstract

This study presents an experimental investigation aimed at addressing charge air cooler (CAC) delta temperature variation and air pulsation issues encountered during final vehicle calibration on engine dynamometers. Conventional calibration setups typically employ customized water-cooled CAC systems, which often fail to replicate actual vehicle conditions, leading to discrepancies in pressure, temperature, and air-fuel ratio (AFR). To overcome this limitation, a novel air-to-air (A2A) CAC configuration incorporating a dynamically controlled airflow system using a variable frequency drive (VFD) and a closed-loop PID controller was implemented on the engine dynamometer. The proposed setup enables accurate emulation of vehicle charge air temperature and pressure conditions under both stationary and transient operating modes. Experimental results demonstrate a significant reduction in pressure drop from 10 kPa to 1.2 kPa and improved temperature control from 49 °C to 39 °C, resulting in an efficiency improvement of approximately 6-8% compared to conventional water-cooled systems. The optimized CAC performance contributes to improved air density, stable AFR, reduced air pulsation (pumping loss), and enhanced overall engine efficiency. The findings confirm that the proposed methodology effectively replicates real vehicle conditions on the dynamometer, thereby minimizing iterative calibration efforts, reducing development time and cost, and improving reliability in OEM calibration processes.

Scientific Reports
Bule Hora University (ET), Robert Bosch (India) (IN), Institute of Chartered Financial Analysts of India (IN), King Khalid University (SA), Dr. Hari Singh Gour University (IN)
King Khalid University
Affordable and clean energy
Openalex Percentile: Top 2%
Aerodynamics and Fluid Dynamics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.