Iatrogenic Tracheal Injury during Cardiac Surgery
A 59-year-old man was taken up for coronary artery bypass graft surgery.After an uneventful anesthetic induction and intubation with a cuffed endotracheal tube (ETT) of internal diameter 8.5 mm, the surgeon used electrocautery in the suprasternal space for the division of the interclavicular ligament before sternotomy.At this point, a low tidal-volume alarm from the anesthesia machine was noted, and end-tidal carbon dioxide tracing suddenly became flat.e breathing circuit tubing and its connectors were found intact.e surgeon noticed an air leak sound and air bubbles coming out from the trachea.An injury to the trachea and the cuff of
Authors
- Ajmer Singh
- Munish Sharma
- Shradha Rose Anthappan
Institutions
- Medanta The Medicity (IN)
- Medanta The Medicity (IN)
Publication Details
- Journal
- Journal of Cardiac Critical Care TSS
- Published
- 2026-05-30
- DOI
- https://doi.org/10.25259/jccc_4_2025
- Primary Topic
- Trauma Management and Diagnosis
- Type
- article
- Field-Weighted Citation Impact
- 0.00