DEVELOPMENT AND VALIDATION OF A RAPID, SIMPLE AND COST EFFECTIVE ICP-MS METHOD FOR WHOLE BLOOD TRACE ELEMENT ANALYSIS

Accurate trace metal analysis in whole blood by ICP-MS depends strongly on sample preparation. This study compares three practical pre-treatment strategies: simple acid dilution, non-digestion & microwave digestion, for simultaneous determination of arsenic, lead, cadmium, manganese, chromium, cobalt, and thallium in whole blood. The methods were assessed for analytical recovery, precision, matrix effect, carryover, turnaround time, reagent consumption, & per-sample processing cost. The simple HNO3 dilution method demonstrated the best balance of accuracy, speed, and economy, showing comparable recoveries to digestion for lead (Pb), cadmium (Cd), Arsenic (As), Manganese (Mn), Cobalt (Co), Chromium (Cr) & Thallium(Tl), while significantly reducing sample preparation time and acid usage. The simple HNO3 dilution method demonstrated the equally comparable result with non-digestion Triton X-100/NH3 method & Microwave digestion method.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-05-30
DOI
https://doi.org/10.5281/zenodo.20465327
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF A RAPID, SIMPLE AND COST EFFECTIVE ICP-MS METHOD FOR WHOLE BLOOD TRACE ELEMENT ANALYSIS

Rohit Saxena*1, Nimmi Kansal1, Mah Alam1, Murugesan Suresh2
Zenodo (CERN European Organization for Nuclear Research)
Analytical chemistry methods development
article

DEVELOPMENT AND VALIDATION OF A RAPID, SIMPLE AND COST EFFECTIVE ICP-MS METHOD FOR WHOLE BLOOD TRACE ELEMENT ANALYSIS

Rohit Saxena*1, Nimmi Kansal1, Mah Alam1, Murugesan Suresh2
article en

Abstract

Accurate trace metal analysis in whole blood by ICP-MS depends strongly on sample preparation. This study compares three practical pre-treatment strategies: simple acid dilution, non-digestion & microwave digestion, for simultaneous determination of arsenic, lead, cadmium, manganese, chromium, cobalt, and thallium in whole blood. The methods were assessed for analytical recovery, precision, matrix effect, carryover, turnaround time, reagent consumption, & per-sample processing cost. The simple HNO3 dilution method demonstrated the best balance of accuracy, speed, and economy, showing comparable recoveries to digestion for lead (Pb), cadmium (Cd), Arsenic (As), Manganese (Mn), Cobalt (Co), Chromium (Cr) & Thallium(Tl), while significantly reducing sample preparation time and acid usage. The simple HNO3 dilution method demonstrated the equally comparable result with non-digestion Triton X-100/NH3 method & Microwave digestion method.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 9%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.