Impact of Imaging Modality on AI-Based Detection of Incidental Maxillary Sinus Pathology: Comparison of Panoramic Radiography and CBCT

Background/Objectives: The objective of our study was to compare the diagnostic performance of a popular, commercial dental artificial intelligence (AI) platform (Diagnocat, DGNCT LLC, Miami, FL, USA) for detecting maxillary sinus abnormalities on paired panoramic radiographs (OPG) and cone-beam computed tomography (CBCT) acquired in the same patients, and to examine whether lesion conspicuity predicts correct AI decisions. Methods: In this retrospective paired study, 166 patients contributed 332 maxillary sinuses with OPG and CBCT performed ≤30 days apart. The reference standard was consensus CBCT reading by two observers with third-reader arbitration. The index test was the AI’s sinus-level binary output (any abnormality). Accuracy, precision, recall, and F1 score were estimated with patient-clustered 95% bootstrap CIs; secondary analyses assessed category-specific performance and the effect of mucosal thickness and polyp/cyst volume. Results: Our evaluation showed that the platform’s performance depended on modality. On CBCT, the accuracy was 69.88% (64.76–74.70%), precision was 87.83% (81.58–93.33%), recall was 54.01% (46.74–61.17%), and F1 score was 66.89% (60.34–72.84%). On OPG, the accuracy was 50.6% (44.58–55.41%), precision was 67.80% (55.38–79.66%), recall was 21.39% (15.62–27.32%), and F1 score 32.52% (24.79–39.69%). On CBCT, higher mucosal thickness and larger polyp/cyst volume strongly predicted correct AI calls; no such effect was seen with OPG. Conclusions: In conclusion, the evaluated AI showed high precision but only moderate recall on CBCT and unreliable performance on OPG. Outputs must be interpreted by a professional; AI alerts on OPG should not guide management without CBCT confirmation.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-05-28
DOI
https://doi.org/10.3390/diagnostics16111667
Primary Topic
Sinusitis and nasal conditions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Imaging Modality on AI-Based Detection of Incidental Maxillary Sinus Pathology: Comparison of Panoramic Radiography and CBCT

Natalia Kazimierczak, Wojciech Kazimierczak, Anna Lackowska, Nora Sultani et al.
Diagnostics
Sinusitis and nasal conditions
article

Impact of Imaging Modality on AI-Based Detection of Incidental Maxillary Sinus Pathology: Comparison of Panoramic Radiography and CBCT

Natalia Kazimierczak, Wojciech Kazimierczak, Anna Lackowska, Nora Sultani, Natalia Chwarścianek, Zbigniew Serafin
article en

Abstract

Background/Objectives: The objective of our study was to compare the diagnostic performance of a popular, commercial dental artificial intelligence (AI) platform (Diagnocat, DGNCT LLC, Miami, FL, USA) for detecting maxillary sinus abnormalities on paired panoramic radiographs (OPG) and cone-beam computed tomography (CBCT) acquired in the same patients, and to examine whether lesion conspicuity predicts correct AI decisions. Methods: In this retrospective paired study, 166 patients contributed 332 maxillary sinuses with OPG and CBCT performed ≤30 days apart. The reference standard was consensus CBCT reading by two observers with third-reader arbitration. The index test was the AI’s sinus-level binary output (any abnormality). Accuracy, precision, recall, and F1 score were estimated with patient-clustered 95% bootstrap CIs; secondary analyses assessed category-specific performance and the effect of mucosal thickness and polyp/cyst volume. Results: Our evaluation showed that the platform’s performance depended on modality. On CBCT, the accuracy was 69.88% (64.76–74.70%), precision was 87.83% (81.58–93.33%), recall was 54.01% (46.74–61.17%), and F1 score was 66.89% (60.34–72.84%). On OPG, the accuracy was 50.6% (44.58–55.41%), precision was 67.80% (55.38–79.66%), recall was 21.39% (15.62–27.32%), and F1 score 32.52% (24.79–39.69%). On CBCT, higher mucosal thickness and larger polyp/cyst volume strongly predicted correct AI calls; no such effect was seen with OPG. Conclusions: In conclusion, the evaluated AI showed high precision but only moderate recall on CBCT and unreliable performance on OPG. Outputs must be interpreted by a professional; AI alerts on OPG should not guide management without CBCT confirmation.

DiagnosticsVol. 16(11)
Bydgoszcz University of Science and Technology (PL), Kazimierz Wielki University in Bydgoszcz (PL), Nicolaus Copernicus University (PL), AGH University of Krakow (PL)
Peace, Justice and strong institutions
Openalex Percentile: Top 4%
Sinusitis and nasal conditions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.