Impact of Storage Temperature and Duration on Dimensional Stability and Mechanical Properties of <scp>3D</scp> ‐Printed Implant Surgical Guides
OBJECTIVE: This study aimed to evaluate the impact of storage temperature and duration on the dimensional stability and mechanical properties of 3D-printed surgical guides. MATERIALS AND METHODS: Sixty surgical guides were designed using two software programs (3Shape and SMOP) and printed with NextDent SG resin. Specimens were stored at 2°C, 20°C, and 30°C (n = 10). Scans were performed at baseline and after 2, 4, and 6 weeks to assess dimensional stability by using root mean square (RMS) deviation. Additionally, 30 bar-shaped and 30 disk-shaped specimens were printed (n = 10) to evaluate flexural strength, flexural modulus, and hardness after 6 weeks of storage at the respective temperatures. RESULTS: Storage temperature had no significant effect on dimensional stability for 3Shape or SMOP. However, RMS values increased significantly from 2 to 6 weeks for both groups. In standardized mechanical specimens, storage temperature significantly affected flexural strength (p < 0.001) and flexural modulus (p = 0.018), but not Vickers hardness (p = 0.126). Flexural strength was highest at 30°C, while 2°C and 20°C did not differ significantly (p = 0.772). Flexural modulus was higher at 20°C than at 2°C (p = 0.038). CONCLUSIONS: Storage temperature did not affect dimensional stability or hardness but influenced flexural properties in standardized specimens. Time-dependent dimensional changes were detected. Based on mechanical data, storage at 20°C or 30°C may be preferable to refrigeration for maintaining flexural performance. CLINICAL SIGNIFICANCE: 3D-printed surgical guides demonstrated dimensional stability across varying storage temperatures, although time-dependent deviations were detected. Based on standardized mechanical specimens, refrigeration may not provide mechanical benefits compared with room-temperature storage. Therefore, room-temperature storage may be preferable when delayed use is expected, even in warmer climates.
Authors
- Jin‐Soo Ahn (ORCID: https://orcid.org/0000-0001-6978-5342)
- Vincent Fehmer (ORCID: https://orcid.org/0000-0002-1437-7066)
- René Daher (ORCID: https://orcid.org/0000-0002-1586-6224)
- Koungjin Park (ORCID: https://orcid.org/0000-0002-2678-1912)
- Sung‐Jin Kim (ORCID: https://orcid.org/0009-0005-7738-4895)
- Jae‐Hyun Lee (ORCID: https://orcid.org/0000-0002-2631-7722)
Institutions
- University of Geneva (CH)
- Seoul National University (KR)
- Seoul National University Dental Hospital (KR)
Publication Details
- Journal
- Journal of Esthetic and Restorative Dentistry
- Published
- 2026-05-29
- DOI
- https://doi.org/10.1111/jerd.70198
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Research Foundation of Korea
- Seoul National University Dental Hospital