Development and Preliminary Validation of a MALDI-TOF MS Assay Using KTI as an Internal Standard for Serum M-Protein Light Chain Analysis in Multiple Myeloma: A Pilot Study

Background and Objectives: Conventional assays for M-protein detection in multiple myeloma (MM), including serum immunofixation electrophoresis (sIFE) and serum free light-chain (sFLC) assays, have limitations in selected clinical settings. This pilot study aimed to develop and preliminarily validate a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based workflow using Kunitz trypsin inhibitor (KTI) as an internal standard for patient-specific serum M-protein light-chain tracking, particularly in low-level post-treatment samples in which conventional assays may be negative or difficult to interpret. Materials and Methods: A total of 55 serum samples from 25 patients with MM were analyzed. Serum immunoglobulin light-chain species were enriched using mixed κ/λ affinity beads, followed by reduction, KTI-based calibration, and MALDI-TOF MS analysis. Quantitative performance was evaluated using purified IgG1 κ standards. Time-matched sIFE and sFLC ratio results were used for descriptive comparison. Results: After KTI-based calibration, patient-specific M-protein light-chain molecular masses could be consistently identified. The assay showed good linearity over the range of 0.20–10.00 μg/mL, with a calibration equation of y = 6.0228x + 0.1063 and an R2 of 0.9961. The limit of detection and limit of quantification were 0.002 μg/mL and 0.008 μg/mL, respectively. Intra-day and inter-day precision were acceptable, and recovery ranged from 96.0% to 101.2%. In selected low-level or discordant samples, including cases with therapeutic interference, polyclonal background, or non-secretory disease, MALDI-TOF MS provided exploratory complementary monitoring information. Conclusions: This KTI-calibrated MALDI-TOF MS workflow showed preliminary analytical performance within the validated low-concentration range and may serve as a complementary approach for patient-specific serum M-protein light-chain monitoring in selected clinical settings of MM. Larger independent studies are required before its clinical utility can be established.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2026-05-29
DOI
https://doi.org/10.3390/medicina62061057
Primary Topic
Multiple Myeloma Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Preliminary Validation of a MALDI-TOF MS Assay Using KTI as an Internal Standard for Serum M-Protein Light Chain Analysis in Multiple Myeloma: A Pilot Study

Shuanglian Xie, Zhizhen Lai, Mingyi Di, H Liu et al.
Medicina
Multiple Myeloma Research and Treatments
article

Development and Preliminary Validation of a MALDI-TOF MS Assay Using KTI as an Internal Standard for Serum M-Protein Light Chain Analysis in Multiple Myeloma: A Pilot Study

Shuanglian Xie, Zhizhen Lai, Mingyi Di, H Liu, Yi-Xiang Wang, Y H Dong, Xiaoying Yang, Weiwei Xie, Bo Tang, Yiming Zhao, Bingjie Wang
article en

Abstract

Background and Objectives: Conventional assays for M-protein detection in multiple myeloma (MM), including serum immunofixation electrophoresis (sIFE) and serum free light-chain (sFLC) assays, have limitations in selected clinical settings. This pilot study aimed to develop and preliminarily validate a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based workflow using Kunitz trypsin inhibitor (KTI) as an internal standard for patient-specific serum M-protein light-chain tracking, particularly in low-level post-treatment samples in which conventional assays may be negative or difficult to interpret. Materials and Methods: A total of 55 serum samples from 25 patients with MM were analyzed. Serum immunoglobulin light-chain species were enriched using mixed κ/λ affinity beads, followed by reduction, KTI-based calibration, and MALDI-TOF MS analysis. Quantitative performance was evaluated using purified IgG1 κ standards. Time-matched sIFE and sFLC ratio results were used for descriptive comparison. Results: After KTI-based calibration, patient-specific M-protein light-chain molecular masses could be consistently identified. The assay showed good linearity over the range of 0.20–10.00 μg/mL, with a calibration equation of y = 6.0228x + 0.1063 and an R2 of 0.9961. The limit of detection and limit of quantification were 0.002 μg/mL and 0.008 μg/mL, respectively. Intra-day and inter-day precision were acceptable, and recovery ranged from 96.0% to 101.2%. In selected low-level or discordant samples, including cases with therapeutic interference, polyclonal background, or non-secretory disease, MALDI-TOF MS provided exploratory complementary monitoring information. Conclusions: This KTI-calibrated MALDI-TOF MS workflow showed preliminary analytical performance within the validated low-concentration range and may serve as a complementary approach for patient-specific serum M-protein light-chain monitoring in selected clinical settings of MM. Larger independent studies are required before its clinical utility can be established.

MedicinaVol. 62(6)
Peking University (CN), Peking University First Hospital (CN)
Natural Science Foundation of Beijing Municipality, National Key Research and Development Program of China
Openalex Percentile: Top 6%
Multiple Myeloma Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.