Isotope Decluttering Reduces Spectral Complexity while Maintaining Protein Structure

Accurate mass determination is one of the fundamental objectives in mass spectrometry (MS) as it enables confident molecular identification and detection of subtle mass differences. Precise mass determination typically relies on the measurement of the monoisotopic peak. The increasing number of heavier isotopes, as the molecular mass increases, leads to spectral complexity, broadening of the isotopic distribution, and dispersal of signal intensity, ultimately reducing the signal-to-noise ratio (SNR). These effects are enhanced while analyzing larger proteins and protein complexes. In this study, we expressed and purified two Mycobacterium tuberculosis protein complexes, EsxAB and bacterioferritin B (BfrB), under isotope-depleted conditions to reduce the abundances of the heavier isotopes of carbon and nitrogen. We applied isotope depletion to BfrB, which represents the largest mass of the isotope-depleted protein complex studied under native conditions to date, and, for the first time, investigated its structural consequences. Isotope-depleted proteins as well as protein complexes showed simplified mass spectra by reducing the isotopic distribution, with a significant increase in the SNR of the monoisotopic peak followed by improved protein sequence coverage by native top-down MS. Furthermore, our investigation of protein structure, by single-particle analysis using cryo-electron microscopy (cryo-EM), demonstrated that isotope depletion preserves the structural integrity of proteins, even at atomic resolution. Collectively, our findings show that isotope depletion is a suitable method for high-accuracy mass measurement and identification by MS while maintaining the structural integrity of the proteins.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-05-29
DOI
https://doi.org/10.1021/acs.analchem.5c08046
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Isotope Decluttering Reduces Spectral Complexity while Maintaining Protein Structure

Birol Cabukusta, David P. A. Kilgour, Kèvin Knoops, Anjusha Mathew et al.
Analytical Chemistry
Mass Spectrometry Techniques and Applications
article

Isotope Decluttering Reduces Spectral Complexity while Maintaining Protein Structure

Birol Cabukusta, David P. A. Kilgour, Kèvin Knoops, Anjusha Mathew, David J. Clarke, Willem E. M. Noteborn, Ye Gao, Carmen López-Iglesias, Ron M.A Heeren, Sneha S. Hakke
article en

Abstract

Accurate mass determination is one of the fundamental objectives in mass spectrometry (MS) as it enables confident molecular identification and detection of subtle mass differences. Precise mass determination typically relies on the measurement of the monoisotopic peak. The increasing number of heavier isotopes, as the molecular mass increases, leads to spectral complexity, broadening of the isotopic distribution, and dispersal of signal intensity, ultimately reducing the signal-to-noise ratio (SNR). These effects are enhanced while analyzing larger proteins and protein complexes. In this study, we expressed and purified two Mycobacterium tuberculosis protein complexes, EsxAB and bacterioferritin B (BfrB), under isotope-depleted conditions to reduce the abundances of the heavier isotopes of carbon and nitrogen. We applied isotope depletion to BfrB, which represents the largest mass of the isotope-depleted protein complex studied under native conditions to date, and, for the first time, investigated its structural consequences. Isotope-depleted proteins as well as protein complexes showed simplified mass spectra by reducing the isotopic distribution, with a significant increase in the SNR of the monoisotopic peak followed by improved protein sequence coverage by native top-down MS. Furthermore, our investigation of protein structure, by single-particle analysis using cryo-electron microscopy (cryo-EM), demonstrated that isotope depletion preserves the structural integrity of proteins, even at atomic resolution. Collectively, our findings show that isotope depletion is a suitable method for high-accuracy mass measurement and identification by MS while maintaining the structural integrity of the proteins.

Analytical Chemistry
Leiden University (NL), Maastricht University (NL), Advanced Research Center for Nanolithography (Netherlands) (NL), Vibrant Data (United States) (US), Laboratory for Research on Enterprise and Decisions, University of Edinburgh (GB), Core Laboratories (United States) (US)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Provincie Limburg
Openalex Percentile: Top 10%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines