A Consistent Landmark for Tibial Tunnel Placement in Arthroscopic Remnant-Preserving Posterior Cruciate Ligament Reconstruction: Use of Champagne-Glass Drop-Off and Lateral Cartilage Point—A Retrospective Case Series

Background/Objectives: Accurate tibial tunnel placement is critical for successful posterior cruciate ligament reconstruction (PCLR), yet remains technically demanding due to limited visualization and anatomic variability. This study aimed to demonstrate the feasibility of an arthroscopic technique for remnant-preserving PCLR using the champagne-glass drop-off and lateral cartilage point as consistently identifiable arthroscopic anatomic bony landmarks, and to evaluate the success rate of tibial tunnel placement in targeted position using postoperative magnetic resonance imaging (MRI). Methods: A retrospective review was performed of patients who underwent arthroscopic remnant-preserving PCLR using a trans-septal approach with the described dual-landmark technique between March 2020 and October 2022. Of 31 eligible patients, 20 with complete clinical follow-up and postoperative 1-year MRI were included for analysis. Tibial tunnel position was assessed on MRI to determine success rate of placement in the targeted inferior–lateral tibial footprint based on anatomic reference. Clinical outcomes, including knee range of motion and posterior laxity, were also evaluated. Results: MRI evaluation demonstrated tibial tunnel consistent placement with the predefined targeted zone in all patients (20/20). At a median follow-up of 745 days, the mean knee range of motion was 140.0 ± 12.7 degrees. Posterior stability assessment showed grade 0 laxity in 75% of patients and grade 1 laxity in 25%. No graft failures, neurovascular complications, infections, or revision PCLR procedures were observed. Conclusions: This retrospective case series suggests that the dual-landmark technique (champagne-glass drop-off and lateral cartilage point) may facilitate consistent tibial tunnel placement in remnant-preserving PCLR. Level of Evidence: IV (Retrospective case series).

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-05-29
DOI
https://doi.org/10.3390/diagnostics16111688
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Consistent Landmark for Tibial Tunnel Placement in Arthroscopic Remnant-Preserving Posterior Cruciate Ligament Reconstruction: Use of Champagne-Glass Drop-Off and Lateral Cartilage Point—A Retrospective Case Series

Chien-Sheng Lo, Yu‐Ze Luan, Hong Wei‐Jun, Tzu-Chun Chung
Diagnostics
Knee injuries and reconstruction techniques
article

A Consistent Landmark for Tibial Tunnel Placement in Arthroscopic Remnant-Preserving Posterior Cruciate Ligament Reconstruction: Use of Champagne-Glass Drop-Off and Lateral Cartilage Point—A Retrospective Case Series

Chien-Sheng Lo, Yu‐Ze Luan, Hong Wei‐Jun, Tzu-Chun Chung
article en

Abstract

Background/Objectives: Accurate tibial tunnel placement is critical for successful posterior cruciate ligament reconstruction (PCLR), yet remains technically demanding due to limited visualization and anatomic variability. This study aimed to demonstrate the feasibility of an arthroscopic technique for remnant-preserving PCLR using the champagne-glass drop-off and lateral cartilage point as consistently identifiable arthroscopic anatomic bony landmarks, and to evaluate the success rate of tibial tunnel placement in targeted position using postoperative magnetic resonance imaging (MRI). Methods: A retrospective review was performed of patients who underwent arthroscopic remnant-preserving PCLR using a trans-septal approach with the described dual-landmark technique between March 2020 and October 2022. Of 31 eligible patients, 20 with complete clinical follow-up and postoperative 1-year MRI were included for analysis. Tibial tunnel position was assessed on MRI to determine success rate of placement in the targeted inferior–lateral tibial footprint based on anatomic reference. Clinical outcomes, including knee range of motion and posterior laxity, were also evaluated. Results: MRI evaluation demonstrated tibial tunnel consistent placement with the predefined targeted zone in all patients (20/20). At a median follow-up of 745 days, the mean knee range of motion was 140.0 ± 12.7 degrees. Posterior stability assessment showed grade 0 laxity in 75% of patients and grade 1 laxity in 25%. No graft failures, neurovascular complications, infections, or revision PCLR procedures were observed. Conclusions: This retrospective case series suggests that the dual-landmark technique (champagne-glass drop-off and lateral cartilage point) may facilitate consistent tibial tunnel placement in remnant-preserving PCLR. Level of Evidence: IV (Retrospective case series).

DiagnosticsVol. 16(11)
China Medical University (TW), Kuang Tien General Hospital (TW), Chung Shan Medical University Hospital (TW), China Medical University Hospital (TW), Chung Shan Medical University (TW)
Chung Shan Medical University Hospital
Openalex Percentile: Top 5%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.