Crestal Bone Loss and Peri-Implant Conditions at Tissue-Level Implants: Influence of Prosthesis Type After 25 Years.

Objective To evaluate long-term crestal bone level changes (ΔCBL) and prevalence of peri-implant conditions according to the type of implant-supported fixed dental prosthesis (IFDP), and to identify implant-, prosthetic-, and patient-related factors associated with ΔCBL.Materials And Methods This single-center observational study evaluated patients rehabilitated with single crowns (SCs), splinted crowns (SPs), or bridges (BRs) on tissue-level implants after 10 and 25 years of function. Standardized clinical and radiographic evaluations were performed, and peri-implant conditions were diagnosed according to established consensus definitions.Results A total of 147 patients with 233 implants were included. The prevalence of peri-implantitis (PI) increased from 10 to 25 years, from 2.3% to 7.8% for SC, from 1.6% to 6.3% for SP, and from 0% to 4.9% for BR, with no significant differences between IFDP types at either time point (p ≥ 0.95). SP tended to have higher peri-implant mucositis (PM) rates at 25 years (87.3%), compared to SC (74.4%) and BR (80.5%). Mean ΔCBL was -0.37 ± 0.91 mm for SC, -0.25 ± 0.85 mm for SP, and -0.70 ± 1.0 mm for BR, with no significant differences between IFDP types (p = 0.37). Multivariate analyses demonstrated that greater ΔCBL was significantly associated with incisor region location (-0.74 mm), increased probing depth (-0.16 mm per mm), and suppuration on probing (-0.97 mm), all p ≤ 0.05. In contrast, prosthetic retention, marginal misfit, and prosthet emergence geometry were not significantly associated with ΔCBL.Conclusions Over 25 years, the type of IFDP did not significantly affect ΔCBL or the prevalence of PM and PI around tissue-level implants. Long-term bone stability was primarily influenced by implant location in the incisor region, increased probing depths, and the presence of suppuration.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-05-29
DOI
https://doi.org/10.48620/98203
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Crestal Bone Loss and Peri-Implant Conditions at Tissue-Level Implants: Influence of Prosthesis Type After 25 Years.

Andrea Roccuzzo, Manrique Fonseca, Clemens Raabe, Vivianne Chappuis et al.
Open Access CRIS of the University of Bern
Dental Implant Techniques and Outcomes
article

Crestal Bone Loss and Peri-Implant Conditions at Tissue-Level Implants: Influence of Prosthesis Type After 25 Years.

Andrea Roccuzzo, Manrique Fonseca, Clemens Raabe, Vivianne Chappuis, Emilio Couso-Queiruga, Giovanni E. Salvi, Martin Schimmel
article en

Abstract

Objective To evaluate long-term crestal bone level changes (ΔCBL) and prevalence of peri-implant conditions according to the type of implant-supported fixed dental prosthesis (IFDP), and to identify implant-, prosthetic-, and patient-related factors associated with ΔCBL.Materials And Methods This single-center observational study evaluated patients rehabilitated with single crowns (SCs), splinted crowns (SPs), or bridges (BRs) on tissue-level implants after 10 and 25 years of function. Standardized clinical and radiographic evaluations were performed, and peri-implant conditions were diagnosed according to established consensus definitions.Results A total of 147 patients with 233 implants were included. The prevalence of peri-implantitis (PI) increased from 10 to 25 years, from 2.3% to 7.8% for SC, from 1.6% to 6.3% for SP, and from 0% to 4.9% for BR, with no significant differences between IFDP types at either time point (p ≥ 0.95). SP tended to have higher peri-implant mucositis (PM) rates at 25 years (87.3%), compared to SC (74.4%) and BR (80.5%). Mean ΔCBL was -0.37 ± 0.91 mm for SC, -0.25 ± 0.85 mm for SP, and -0.70 ± 1.0 mm for BR, with no significant differences between IFDP types (p = 0.37). Multivariate analyses demonstrated that greater ΔCBL was significantly associated with incisor region location (-0.74 mm), increased probing depth (-0.16 mm per mm), and suppuration on probing (-0.97 mm), all p ≤ 0.05. In contrast, prosthetic retention, marginal misfit, and prosthet emergence geometry were not significantly associated with ΔCBL.Conclusions Over 25 years, the type of IFDP did not significantly affect ΔCBL or the prevalence of PM and PI around tissue-level implants. Long-term bone stability was primarily influenced by implant location in the incisor region, increased probing depths, and the presence of suppuration.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM), Stomatology Hospital (CN)
Openalex Percentile: Top 5%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.