FEASIBILITY JUSTIFICATION FOR A HYBRID ULTRASONIC FLOWMETER FOR NATURAL GAS
The possibility of creating a hybrid ultrasonic flowmeter of natural gas is presented, which combines a fourchannel ultrasonic transit-time method (TOF) and a resonance method. A mathematical description of such a flowmeter is given, the errors of the classical and the proposed flowmeter are estimated, the gain in accuracy and resistance to external factors are shown.
Authors
- Yosyp Bilynskyi
- Andrii Stetsenko
Institutions
- National Technical University of Athens (GR)
- Vinnytsia National Technical University (UA)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-05-29
- DOI
- https://doi.org/10.5281/zenodo.20445320
- Primary Topic
- Flow Measurement and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00