See, feel, fail? A prospective observational study on the accuracy of vein identification methods

BACKGROUND: Visualization and palpation are standard methods for identifying peripheral IV sites. Vein diameter and depth significantly influence catheter dwell time and complication rates. This study aimed to determine the diagnostic performance of visualization and palpation in determining suitability for cannulation. METHODS: In this prospective observational study, healthy adult volunteers were enrolled from a senior recreational facility and an office setting. Two vascular access nurses independently assessed both arms of each participant using the Vascular Access Score (VAS): 1 = easily palpable, distended, visible; 2 = easily palpable, not distended, visible; 3 = easily palpable, not visible; 4 = poorly palpable, visible; 5 = nonpalpable, not visible. Scores of 1-3 were considered suitable for traditional cannulation, and scores of 4-5 were considered unsuitable, prompting escalation. Ultrasound was used to measure vein parameters with vein diameter ⩽0.3 cm and vein depth >0.4 cm considered suboptimal. Primary outcome was diagnostic accuracy. RESULTS: ; 93% identified as Caucasian. Mean vein depth was 0.35 cm (26.2% > 0.4 cm) and mean diameter 0.35 cm (47.8% ⩽ 0.3 cm). After adjudication, and after excluding hand and wrist sites as well as missing values, VAS distribution with 483 IV sites was 1 = 22.77%, 2 = 4.76%, 3 = 53.21%, 4 = 7.45%, 5 = 11.80%. The sensitivity of visualization/palpation method for determining if the vein was suitable for traditional insertion was 99.32%, specificity was 27.46%, PPV was 37.69%, NPV was 98.92%, and accuracy was 49.48%. CONCLUSION: Vein assessment via standard visualization/palpation effectively rules out inappropriate sites and should trigger early ultrasound escalation. However, clinically "suitable" veins are frequently suboptimal on ultrasound, supporting broader use of ultrasound to guide initial cannulation decisions.

Authors

Institutions

Publication Details

Journal
The Journal of Vascular Access
Published
2026-05-29
DOI
https://doi.org/10.1177/11297298261451303
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

See, feel, fail? A prospective observational study on the accuracy of vein identification methods

Amit Bahl, S. Matthew Gibson, Heather L Cook
The Journal of Vascular Access
Central Venous Catheters and Hemodialysis
article

See, feel, fail? A prospective observational study on the accuracy of vein identification methods

Amit Bahl, S. Matthew Gibson, Heather L Cook
article en

Abstract

BACKGROUND: Visualization and palpation are standard methods for identifying peripheral IV sites. Vein diameter and depth significantly influence catheter dwell time and complication rates. This study aimed to determine the diagnostic performance of visualization and palpation in determining suitability for cannulation. METHODS: In this prospective observational study, healthy adult volunteers were enrolled from a senior recreational facility and an office setting. Two vascular access nurses independently assessed both arms of each participant using the Vascular Access Score (VAS): 1 = easily palpable, distended, visible; 2 = easily palpable, not distended, visible; 3 = easily palpable, not visible; 4 = poorly palpable, visible; 5 = nonpalpable, not visible. Scores of 1-3 were considered suitable for traditional cannulation, and scores of 4-5 were considered unsuitable, prompting escalation. Ultrasound was used to measure vein parameters with vein diameter ⩽0.3 cm and vein depth >0.4 cm considered suboptimal. Primary outcome was diagnostic accuracy. RESULTS: ; 93% identified as Caucasian. Mean vein depth was 0.35 cm (26.2% > 0.4 cm) and mean diameter 0.35 cm (47.8% ⩽ 0.3 cm). After adjudication, and after excluding hand and wrist sites as well as missing values, VAS distribution with 483 IV sites was 1 = 22.77%, 2 = 4.76%, 3 = 53.21%, 4 = 7.45%, 5 = 11.80%. The sensitivity of visualization/palpation method for determining if the vein was suitable for traditional insertion was 99.32%, specificity was 27.46%, PPV was 37.69%, NPV was 98.92%, and accuracy was 49.48%. CONCLUSION: Vein assessment via standard visualization/palpation effectively rules out inappropriate sites and should trigger early ultrasound escalation. However, clinically "suitable" veins are frequently suboptimal on ultrasound, supporting broader use of ultrasound to guide initial cannulation decisions.

The Journal of Vascular Access
University of Southern Indiana (US), Oakland University (US), Cranbrook Academy of Art (US)
Openalex Percentile: Top 4%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.