Dynamic Compensation Implementation for High-Frequency Electrosurgical Unit Testing Using High-Frequency LCR or Network Analyzers Above MHz

This technical document presents a dynamic compensation method for high-frequency electrosurgical unit (ESU) testing using high-frequency LCR meters or network analyzers. The method addresses measurement errors caused by parasitic capacitance and inductance in resistive components above 1 MHz. By using real-time impedance measurement, dynamic modeling, and adaptive compensation algorithms, the proposed approach improves ESU testing accuracy. Experimental results show that within the 1 MHz to 5 MHz range, impedance error is reduced from 14.8% to 1.8%, while phase error is reduced from 9.8 degrees to 0.8 degrees.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-05-29
DOI
https://doi.org/10.5281/zenodo.20441785
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Compensation Implementation for High-Frequency Electrosurgical Unit Testing Using High-Frequency LCR or Network Analyzers Above MHz

Xiaolong Qiang, Jiming Liu, Chao Zhang, Chao Shan
Zenodo (CERN European Organization for Nuclear Research)
Electrical and Bioimpedance Tomography
article

Dynamic Compensation Implementation for High-Frequency Electrosurgical Unit Testing Using High-Frequency LCR or Network Analyzers Above MHz

Xiaolong Qiang, Jiming Liu, Chao Zhang, Chao Shan
article en

Abstract

This technical document presents a dynamic compensation method for high-frequency electrosurgical unit (ESU) testing using high-frequency LCR meters or network analyzers. The method addresses measurement errors caused by parasitic capacitance and inductance in resistive components above 1 MHz. By using real-time impedance measurement, dynamic modeling, and adaptive compensation algorithms, the proposed approach improves ESU testing accuracy. Experimental results show that within the 1 MHz to 5 MHz range, impedance error is reduced from 14.8% to 1.8%, while phase error is reduced from 9.8 degrees to 0.8 degrees.

Zenodo (CERN European Organization for Nuclear Research)
ZheJiang Institute For Food and Drug Control (CN), The Medical Device (United Kingdom) (GB), State Institute for Drug Control (CZ)
Openalex Percentile: Top 9%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dynamic Compensation Implementation for High-Frequency Electrosurgical Unit Testing Using High-Frequency LCR or Network Analyzers Above MHz — Xiaolong Qiang, Jiming Liu, et al. · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS