Airway segmentation on CT – A systematic review of machine learning tools

<h2>Abstract</h2><h3>Background</h3> Airway assessment on computed tomography (CT) can yield clinically useful information for diagnosis, treatment planning and monitoring in respiratory diseases. Manual airway segmentation is time-consuming, prone to error and poorly reproducible. This systematic review aimed to appraise machine learning (ML) methods for fully automated airway segmentation in chest CT imaging. <h3>Methods</h3> EMBASE, MEDLINE and CENTRAL were searched on October 28, 2025, for studies which used fully automated ML methods for airway segmentation on CT and reported quantitative performance metrics. The quality of included studies was assessed by the Must AI Criteria-10 (MAIC-10) checklist. PROSPERO [CRD42025635504] <h3>Results</h3> Thirty-two studies (28 used deep learning (DL)) published between 2010 and 2025 were included. Airway segmentation was performed on non-contrast CT scans in most studies. Voxel-wise accuracy metrics were generally high with Dice similarity coefficient (DSC) values ranging between 83% and 96%. Airway-specific topological metrics: branch detection rate (BD) and tree length detection rate (TD) showed broader variability (60–95% and 54–95% respectively), with DL methods consistently outperforming classical ML approaches. Fifteen studies conducted external validation (EXACT'09 test set used in 9/15). MAIC-10 was moderate and ranged from 6 to 8 out of 10, with lowest reporting in safety/privacy (31%), explainability (31%) and transparency (53%). <h3>Conclusion</h3> ML models achieved strong airway segmentation accuracy but showed considerable variation in topological completeness. Standardised evaluation frameworks and the adoption of more diverse datasets are needed to strengthen model generalisability and support translation into clinical practice.

Authors

Institutions

Publication Details

Journal
European Journal of Radiology Open
Published
2026-05-30
DOI
https://doi.org/10.1016/j.ejro.2026.100764
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Airway segmentation on CT – A systematic review of machine learning tools

Krit Dwivedi, Alireza Hokmabadi, Turki Alnasser, Ahmed Maiter et al.
European Journal of Radiology Open
Obstructive Sleep Apnea Research
article

Airway segmentation on CT – A systematic review of machine learning tools

Krit Dwivedi, Alireza Hokmabadi, Turki Alnasser, Ahmed Maiter, Mahan Salehi, Khalid A Alghamdi, Chris Johns, Nada Lsloum, Michael Sharkey, Andrew J. Swift, Samer Alabed, Ahod Albylwi
article en

Abstract

<h2>Abstract</h2><h3>Background</h3> Airway assessment on computed tomography (CT) can yield clinically useful information for diagnosis, treatment planning and monitoring in respiratory diseases. Manual airway segmentation is time-consuming, prone to error and poorly reproducible. This systematic review aimed to appraise machine learning (ML) methods for fully automated airway segmentation in chest CT imaging. <h3>Methods</h3> EMBASE, MEDLINE and CENTRAL were searched on October 28, 2025, for studies which used fully automated ML methods for airway segmentation on CT and reported quantitative performance metrics. The quality of included studies was assessed by the Must AI Criteria-10 (MAIC-10) checklist. PROSPERO [CRD42025635504] <h3>Results</h3> Thirty-two studies (28 used deep learning (DL)) published between 2010 and 2025 were included. Airway segmentation was performed on non-contrast CT scans in most studies. Voxel-wise accuracy metrics were generally high with Dice similarity coefficient (DSC) values ranging between 83% and 96%. Airway-specific topological metrics: branch detection rate (BD) and tree length detection rate (TD) showed broader variability (60–95% and 54–95% respectively), with DL methods consistently outperforming classical ML approaches. Fifteen studies conducted external validation (EXACT'09 test set used in 9/15). MAIC-10 was moderate and ranged from 6 to 8 out of 10, with lowest reporting in safety/privacy (31%), explainability (31%) and transparency (53%). <h3>Conclusion</h3> ML models achieved strong airway segmentation accuracy but showed considerable variation in topological completeness. Standardised evaluation frameworks and the adoption of more diverse datasets are needed to strengthen model generalisability and support translation into clinical practice.

European Journal of Radiology OpenVol. 16
King Saud bin Abdulaziz University for Health Sciences (SA), Sheffield Teaching Hospitals NHS Foundation Trust (GB), Insigneo (GB), Najran University (SA), University of Sheffield (GB)
Wellcome Trust, British Heart Foundation
Openalex Percentile: Top 7%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.