Is there already value in “Total Body PET” imaging in Neurology?

TBP represents a step change for all of PET, and brain imaging is no exception. Multiple benefits are already being seen. Lower injected doses benefit patients and staff and facilitate multitracer research. Shortened acquisition times for suitable radiopharmaceuticals enable better patient comfort and reduce the need for general anaesthesia in children (albeit then partially negating the dose benefit). Later scanning enabled by the higher sensitivity palliates restrictions in tracer availability and allows better modelling. The large axial field-of-view enables better quantification via assessment of intravascular radioactivity concentrations. Early short-frame dynamic scanning has already enabled obtaining quantitative brain perfusion measurements for several radiopharmaceuticals. The large field-of-view allows assessment of brain-body interactions and multiorgan repercussions of disease. Despite some technical and methodological challenges remaining, TBP already offers added value in brain imaging, with exciting times ahead.

Authors

Institutions

Publication Details

Journal
British Journal of Radiology
Published
2026-05-29
DOI
https://doi.org/10.1093/bjr/tqag126
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is there already value in “Total Body PET” imaging in Neurology?

Alexander Hammers
British Journal of Radiology
Medical Imaging Techniques and Applications
article

Is there already value in “Total Body PET” imaging in Neurology?

Alexander Hammers
article en

Abstract

TBP represents a step change for all of PET, and brain imaging is no exception. Multiple benefits are already being seen. Lower injected doses benefit patients and staff and facilitate multitracer research. Shortened acquisition times for suitable radiopharmaceuticals enable better patient comfort and reduce the need for general anaesthesia in children (albeit then partially negating the dose benefit). Later scanning enabled by the higher sensitivity palliates restrictions in tracer availability and allows better modelling. The large axial field-of-view enables better quantification via assessment of intravascular radioactivity concentrations. Early short-frame dynamic scanning has already enabled obtaining quantitative brain perfusion measurements for several radiopharmaceuticals. The large field-of-view allows assessment of brain-body interactions and multiorgan repercussions of disease. Despite some technical and methodological challenges remaining, TBP already offers added value in brain imaging, with exciting times ahead.

British Journal of Radiology
King's College London (GB)
Openalex Percentile: Top 6%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.