Measures of Equivalent Hemodialysis Urea Clearance and Their Proposed Utility for Monitoring Adequacy

The details of four measures of "equivalent" clearances based on urea that have been proposed to monitor hemodialysis adequacy are reviewed. These measures fall into two groups: one based on urea nitrogen generation rate divided by the time-averaged serum urea nitrogen concentration, and the other based on urea nitrogen generation rate divided by the average predialysis serum urea nitrogen concentration. After the original variants were proposed, a potential problem regarding relative weights of dialysis and residual kidney clearances was identified, and revised equivalent urea clearances were proposed that give a higher weight to residual kidney clearance relative to dialysis clearance. These measures suggest that the target dialysis dose should be set to achieve dialysis solute concentrations typically found in patients at the point of needing dialysis, e.g., with a glomerular filtration rate of around 10 mL/min, corresponding to a urea clearance of approximately 6 mL/min and a creatinine clearance of 14. Despite the theoretical attractiveness of equivalent urea clearances to monitor hemodialysis adequacy, their utility has not been conclusively demonstrated in observational studies of incremental or more frequent hemodialysis.

Authors

Institutions

Publication Details

Journal
Seminars in Dialysis
Published
2026-05-28
DOI
https://doi.org/10.1111/sdi.70036
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measures of Equivalent Hemodialysis Urea Clearance and Their Proposed Utility for Monitoring Adequacy

John T. Daugirdas
Seminars in Dialysis
Dialysis and Renal Disease Management
article

Measures of Equivalent Hemodialysis Urea Clearance and Their Proposed Utility for Monitoring Adequacy

John T. Daugirdas
article en

Abstract

The details of four measures of "equivalent" clearances based on urea that have been proposed to monitor hemodialysis adequacy are reviewed. These measures fall into two groups: one based on urea nitrogen generation rate divided by the time-averaged serum urea nitrogen concentration, and the other based on urea nitrogen generation rate divided by the average predialysis serum urea nitrogen concentration. After the original variants were proposed, a potential problem regarding relative weights of dialysis and residual kidney clearances was identified, and revised equivalent urea clearances were proposed that give a higher weight to residual kidney clearance relative to dialysis clearance. These measures suggest that the target dialysis dose should be set to achieve dialysis solute concentrations typically found in patients at the point of needing dialysis, e.g., with a glomerular filtration rate of around 10 mL/min, corresponding to a urea clearance of approximately 6 mL/min and a creatinine clearance of 14. Despite the theoretical attractiveness of equivalent urea clearances to monitor hemodialysis adequacy, their utility has not been conclusively demonstrated in observational studies of incremental or more frequent hemodialysis.

Seminars in Dialysis
University of Illinois Chicago (US)
Openalex Percentile: Top 6%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.