Thoracic electrical impedance tomography using a two‐plane electrode configuration in horses

Abstract Background Traditional one‐plane (oneP) electrical impedance tomography (EIT) electrode configurations limit evaluation to a convex lens‐shaped lung slice, prone to overrepresentation of central areas. Two‐plane (twoP) EIT is expected to refine this technique and result in more representative lung imaging. Objectives To compare ventilation distribution using single slice reconstructions, obtained with twoP or oneP. Study Design Computational modelling and in vivo exploratory randomised experimental trial. Methods A finite element simulation model of oneP and twoP was calculated to estimate captured lung fields. Thereafter, twoP and oneP EIT data were collected in 20 standing horses at baseline, during stance variations and rebreathing. A visual functional region of interest representing the lung field was defined and EIT data reconstructed. Centres of ventilation (CoV), regional ventilation (∆Z, expressed as L or R for left or right lung, and D, CD, CV, or V for dorsal, central dorsal, central ventral or ventral regions) and tidal impedance variation (TIV) were compared between configurations at baseline and between baseline and challenge measurements using Wilcoxon matched pairs signed rank test and a mixed effect model. Proportional changes were compared using a paired t ‐test. Results The simulation revealed a more evenly distributed vertical sensitivity with twoP compared to oneP. In vivo data were analysed to determine which EIT regional parameters increased (twoP vs. oneP). At baseline, ∆ZL D , ∆ZR D and CoV VD , were higher when using twoP (7.1 (5.9–8.0) vs. 2.2 (0.9–3.5): p < 0.001; 6.4 (5.6–7.5) vs. 1.5 (0.5–2.79): p < 0.001; 47.7 (46.8–49.29) vs. 43.3 (42.2–45.8): p < 0.001). With rebreathing, an increase in TIV and CoV VD was seen with both belt configurations (oneP: 25.13 (±1.967) vs. 49.39 (±11.27): p < 0.001 and 44.3 (±2.300) vs. 45.64 (±2.243): p = 0.002; twoP: 20.21 (±7.398) vs. 49.6 (±13.09): p < 0.001 and 48.79 (±2.126) vs. 50.38 (±1.783): p = 0.005). Conclusions TwoP EIT reconstructions resulted in a more vertically uniform representation of ventilation in simulation and in vivo. This likely results in an enhanced representation of peripheral lung fields.

Authors

Institutions

Publication Details

Journal
Equine Veterinary Journal
Published
2026-05-28
DOI
https://doi.org/10.1002/evj.70188
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thoracic electrical impedance tomography using a two‐plane electrode configuration in horses

Johannes Peter Schramel, Martina Mosing, Nicole Studer, David Byrne et al.
Equine Veterinary Journal
Electrical and Bioimpedance Tomography
article

Thoracic electrical impedance tomography using a two‐plane electrode configuration in horses

Johannes Peter Schramel, Martina Mosing, Nicole Studer, David Byrne, C Secombe, Anthea Raisis, Jesslyn Cheong, Andy Adler
article en

Abstract

Abstract Background Traditional one‐plane (oneP) electrical impedance tomography (EIT) electrode configurations limit evaluation to a convex lens‐shaped lung slice, prone to overrepresentation of central areas. Two‐plane (twoP) EIT is expected to refine this technique and result in more representative lung imaging. Objectives To compare ventilation distribution using single slice reconstructions, obtained with twoP or oneP. Study Design Computational modelling and in vivo exploratory randomised experimental trial. Methods A finite element simulation model of oneP and twoP was calculated to estimate captured lung fields. Thereafter, twoP and oneP EIT data were collected in 20 standing horses at baseline, during stance variations and rebreathing. A visual functional region of interest representing the lung field was defined and EIT data reconstructed. Centres of ventilation (CoV), regional ventilation (∆Z, expressed as L or R for left or right lung, and D, CD, CV, or V for dorsal, central dorsal, central ventral or ventral regions) and tidal impedance variation (TIV) were compared between configurations at baseline and between baseline and challenge measurements using Wilcoxon matched pairs signed rank test and a mixed effect model. Proportional changes were compared using a paired t ‐test. Results The simulation revealed a more evenly distributed vertical sensitivity with twoP compared to oneP. In vivo data were analysed to determine which EIT regional parameters increased (twoP vs. oneP). At baseline, ∆ZL D , ∆ZR D and CoV VD , were higher when using twoP (7.1 (5.9–8.0) vs. 2.2 (0.9–3.5): p < 0.001; 6.4 (5.6–7.5) vs. 1.5 (0.5–2.79): p < 0.001; 47.7 (46.8–49.29) vs. 43.3 (42.2–45.8): p < 0.001). With rebreathing, an increase in TIV and CoV VD was seen with both belt configurations (oneP: 25.13 (±1.967) vs. 49.39 (±11.27): p < 0.001 and 44.3 (±2.300) vs. 45.64 (±2.243): p = 0.002; twoP: 20.21 (±7.398) vs. 49.6 (±13.09): p < 0.001 and 48.79 (±2.126) vs. 50.38 (±1.783): p = 0.005). Conclusions TwoP EIT reconstructions resulted in a more vertically uniform representation of ventilation in simulation and in vivo. This likely results in an enhanced representation of peripheral lung fields.

Equine Veterinary Journal
University of Veterinary Medicine Vienna (AT), City University of Hong Kong (HK), Murdoch University (AU), Carleton University (CA)
Openalex Percentile: Top 9%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.