Organ size in small infants (The OSSI Study): establishing sonographic reference intervals for abdominal organs in preterm infants

Abstract Accurate ultrasound assessment of abdominal organ size in preterm infants is essential for evaluating growth and detecting abnormalities. However, standardized reference intervals for liver, spleen, and kidney dimensions in preterms below 40 cm body length are lacking. This study aimed to establish reference intervals for these organs. 57 eutrophic preterm infants with a body length below 40 cm (gestational age: 23 4 / 7 —31 5 / 7 weeks; birth length: 29—39.5 cm) were prospectively examined using a standardized ultrasound protocol recommended by the German Society for Ultrasound in Medicine (DEGUM). Craniocaudal liver length, spleen length, and renal volume were measured and correlated with corrected gestational age, body weight, and body length. Reference intervals were calculated from log-transformed data with 95% confidence intervals for reference limits. Portal vein peak velocity before feeding and presence of a patent ductus venosus (PDV) were additionally assessed. Organ dimensions correlated most closely with body weight, followed by body length and corrected gestational age, with renal volume showing the highest correlations overall. Reference intervals for liver, spleen, and renal size showed tight 95% confidence intervals. Portal vein peak velocity ranged from 9—29 cm/s. A PDV was present in 56%; these infants were younger at examination (10.9 vs. 17 days, p = 0.01). Conclusion : This study provides clinically relevant ultrasound reference intervals for abdominal organs in small preterm infants. These measurements may help distinguish physiological from pathological findings and guide clinical decision-making in neonatal care. What is Known: • Ultrasound is the preferred imaging modality for abdominal organ assessment in preterm infants, but standardized sonographic reference intervals for infants with a body length below 40 cm are lacking. What is New: • This study provides the first standardized sonographic reference intervals for liver length, splenic length, and renal volume in preterm infants below 40 cm body length, using a prospective, reproducible protocol aligned with DEGUM recommendations. • Organ size correlated most strongly with body weight, followed by body length and corrected gestational age, with renal volume showing the highest overall correlations across all parameters.

Authors

Institutions

Publication Details

Journal
European Journal of Pediatrics
Published
2026-05-28
DOI
https://doi.org/10.1007/s00431-026-07120-0
Primary Topic
Congenital Anomalies and Fetal Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Organ size in small infants (The OSSI Study): establishing sonographic reference intervals for abdominal organs in preterm infants

Bettina Bohnhorst, Lars Brodowski, Rieke Ringlstetter, Carolin Böhne et al.
European Journal of Pediatrics
Congenital Anomalies and Fetal Surgery
article

Organ size in small infants (The OSSI Study): establishing sonographic reference intervals for abdominal organs in preterm infants

Bettina Bohnhorst, Lars Brodowski, Rieke Ringlstetter, Carolin Böhne, Alexandros Rahn, Doris Franke, Corinna Peter, Lara Klischke, Thomas Müller, Sabine Pirr, Leonie Theis
article en

Abstract

Abstract Accurate ultrasound assessment of abdominal organ size in preterm infants is essential for evaluating growth and detecting abnormalities. However, standardized reference intervals for liver, spleen, and kidney dimensions in preterms below 40 cm body length are lacking. This study aimed to establish reference intervals for these organs. 57 eutrophic preterm infants with a body length below 40 cm (gestational age: 23 4 / 7 —31 5 / 7 weeks; birth length: 29—39.5 cm) were prospectively examined using a standardized ultrasound protocol recommended by the German Society for Ultrasound in Medicine (DEGUM). Craniocaudal liver length, spleen length, and renal volume were measured and correlated with corrected gestational age, body weight, and body length. Reference intervals were calculated from log-transformed data with 95% confidence intervals for reference limits. Portal vein peak velocity before feeding and presence of a patent ductus venosus (PDV) were additionally assessed. Organ dimensions correlated most closely with body weight, followed by body length and corrected gestational age, with renal volume showing the highest correlations overall. Reference intervals for liver, spleen, and renal size showed tight 95% confidence intervals. Portal vein peak velocity ranged from 9—29 cm/s. A PDV was present in 56%; these infants were younger at examination (10.9 vs. 17 days, p = 0.01). Conclusion : This study provides clinically relevant ultrasound reference intervals for abdominal organs in small preterm infants. These measurements may help distinguish physiological from pathological findings and guide clinical decision-making in neonatal care. What is Known: • Ultrasound is the preferred imaging modality for abdominal organ assessment in preterm infants, but standardized sonographic reference intervals for infants with a body length below 40 cm are lacking. What is New: • This study provides the first standardized sonographic reference intervals for liver length, splenic length, and renal volume in preterm infants below 40 cm body length, using a prospective, reproducible protocol aligned with DEGUM recommendations. • Organ size correlated most strongly with body weight, followed by body length and corrected gestational age, with renal volume showing the highest overall correlations across all parameters.

European Journal of PediatricsVol. 185(6)
Medizinische Hochschule Hannover (DE)
Peace, Justice and strong institutions
Openalex Percentile: Top 5%
Congenital Anomalies and Fetal Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.