Identify the Relationships Between Orthokeratology Lens Decentration and Myopia Control Efficacy in Children by Using Pentacam

PURPOSE: To determine orthokeratology (ortho-k) lens decentration and its relationships with annual axial length (AL) changes in children treated with ortho-k. METHODS: This retrospective study included children aged 9 to 15 years treated with ortho-k for at least 1 year. Lens decentration was measured using Pentacam based on the relative positions of the corneal thinnest point, pupil center, and visual center. Annual AL change was analyzed using regression models adjusted for age and target power. RESULTS: In total, 71 eyes from 37 patients (mean age, 10.9 years) were included in the final analysis. The mean follow-up time was 35.0 months. The mean annual AL change was 0.11 mm. According to the customized formula based on the pupil or visual center, greater horizontal and vertical vectors and a larger total distance of decentration were associated with less annual AL change. CONCLUSION: Greater temporal and inferior vectors, as well as a larger total distance of decentration, are associated with greater myopia control efficacy. These findings will help to facilitate the prescription and future design of ortho-k lenses to improve myopia control efficacy.

Authors

Institutions

Publication Details

Journal
Eye & Contact Lens Science & Clinical Practice
Published
2026-05-28
DOI
https://doi.org/10.1097/icl.0000000000001262
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identify the Relationships Between Orthokeratology Lens Decentration and Myopia Control Efficacy in Children by Using Pentacam

Jui-Yen Lin, Ling Yeung, Ho-Min Chen, Yu-Kai Kuo et al.
Eye & Contact Lens Science & Clinical Practice
Ophthalmology and Visual Impairment Studies
article

Identify the Relationships Between Orthokeratology Lens Decentration and Myopia Control Efficacy in Children by Using Pentacam

Jui-Yen Lin, Ling Yeung, Ho-Min Chen, Yu-Kai Kuo, Lan‐Hsin Chuang, Chun-Fu Liu, Yih-Shiou Hwang, Chi-Chun Lai, Hung-Chi Chen
article en

Abstract

PURPOSE: To determine orthokeratology (ortho-k) lens decentration and its relationships with annual axial length (AL) changes in children treated with ortho-k. METHODS: This retrospective study included children aged 9 to 15 years treated with ortho-k for at least 1 year. Lens decentration was measured using Pentacam based on the relative positions of the corneal thinnest point, pupil center, and visual center. Annual AL change was analyzed using regression models adjusted for age and target power. RESULTS: In total, 71 eyes from 37 patients (mean age, 10.9 years) were included in the final analysis. The mean follow-up time was 35.0 months. The mean annual AL change was 0.11 mm. According to the customized formula based on the pupil or visual center, greater horizontal and vertical vectors and a larger total distance of decentration were associated with less annual AL change. CONCLUSION: Greater temporal and inferior vectors, as well as a larger total distance of decentration, are associated with greater myopia control efficacy. These findings will help to facilitate the prescription and future design of ortho-k lenses to improve myopia control efficacy.

Eye & Contact Lens Science & Clinical Practice
National Yang Ming Chiao Tung University (TW), Chang Gung University (TW)
Openalex Percentile: Top 6%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.