Artificial Intelligence-Supported Colorimetric Multibiomarker Sensor to Enable Critical Neonatal Monitoring

Clinical monitoring in the most vulnerable patients, such as newborns, relies on invasive and costly procedures and/or wired sensor surveillance, increasing discomfort and risk for undetected events. Addressing this critical need, we present a noninvasive, AI-supported multibiomarker monitoring sensor capturing multiple critical body functions via colorimetric analysis of body fluids. The sensor is optimized for its use in critically ill preterm neonates, where transepidermal fluid mirrors the interstitial compartment, thereby opening new avenues for future clinical monitoring. The silk-based sensor introduces twelve different colorimetric inks that stabilize labile bioresponsive molecules to a simple, wax-printed paper microfluidic wearable patch to facilitate real-time tracking of biomarkers (temperature (T), pH, sodium (S), and glucose (G)) on a miniaturized surface. Colorimetric responses showed high precision and reproducibility in sensing ranges relevant for neonatal care (T: 32-41 [°C]; pH: 3-9; S: 2.92-29.20 [mg/mL], G: 0.039-0.625 [mg/mL]). Deep learning for color response quantification achieved high-precision estimates (T: 0.455 [°C]; pH: 0.416; S: 0.857 [mg/mL], G:0.019 [mg/mL]; mean absolute error). The sensor's optimized interface for sample collection on skin and its performance under clinically relevant conditions, e.g., increased humidity (80%), tracking on moving object (0.986 AP@IoU = 0.5), sensor shear/rotation, uncontrolled light, as well as successful capture of physiological effects in biological fluids together with its miniaturized design caters to the critical needs of intensified monitoring in high-end patient populations such as neonates.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-05-28
DOI
https://doi.org/10.1021/acssensors.5c04171
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial Intelligence-Supported Colorimetric Multibiomarker Sensor to Enable Critical Neonatal Monitoring

Anne Hilgendorff, Motaharehsadat Heydarian, Giusy Matzeu, Elisabetta Ruggeri et al.
ACS Sensors
Biosensors and Analytical Detection
article

Artificial Intelligence-Supported Colorimetric Multibiomarker Sensor to Enable Critical Neonatal Monitoring

Anne Hilgendorff, Motaharehsadat Heydarian, Giusy Matzeu, Elisabetta Ruggeri, Fiorenzo G. Omenetto, Alejandra Castelblanco, Andreas Flemmer, Kai Foerster, Ahmed Bahnasy, Julia A. Schnabel, Benjamin Schubert
article en

Abstract

Clinical monitoring in the most vulnerable patients, such as newborns, relies on invasive and costly procedures and/or wired sensor surveillance, increasing discomfort and risk for undetected events. Addressing this critical need, we present a noninvasive, AI-supported multibiomarker monitoring sensor capturing multiple critical body functions via colorimetric analysis of body fluids. The sensor is optimized for its use in critically ill preterm neonates, where transepidermal fluid mirrors the interstitial compartment, thereby opening new avenues for future clinical monitoring. The silk-based sensor introduces twelve different colorimetric inks that stabilize labile bioresponsive molecules to a simple, wax-printed paper microfluidic wearable patch to facilitate real-time tracking of biomarkers (temperature (T), pH, sodium (S), and glucose (G)) on a miniaturized surface. Colorimetric responses showed high precision and reproducibility in sensing ranges relevant for neonatal care (T: 32-41 [°C]; pH: 3-9; S: 2.92-29.20 [mg/mL], G: 0.039-0.625 [mg/mL]). Deep learning for color response quantification achieved high-precision estimates (T: 0.455 [°C]; pH: 0.416; S: 0.857 [mg/mL], G:0.019 [mg/mL]; mean absolute error). The sensor's optimized interface for sample collection on skin and its performance under clinically relevant conditions, e.g., increased humidity (80%), tracking on moving object (0.986 AP@IoU = 0.5), sensor shear/rotation, uncontrolled light, as well as successful capture of physiological effects in biological fluids together with its miniaturized design caters to the critical needs of intensified monitoring in high-end patient populations such as neonates.

ACS Sensors
Tufts University (US), Carl von Ossietzky Universität Oldenburg (DE), XLAB (Slovenia) (SI), King's College London (GB), Helmholtz Zentrum München (DE), Department of Physics, Mathematics and Informatics (BY), German Center for Lung Research (DE), Child, Adolescent and Family Mental Health (CA), Technical University of Munich (DE), Ludwig-Maximilians-Universität München (DE)
Deutsche Forschungsgemeinschaft, Bundesministerium für Bildung und Forschung, Helmholtz Association, Deutsches Zentrum für Lungenforschung
Openalex Percentile: Top 10%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.