Geometry-Driven Inertial Focusing and Dielectrophoretic Separation of Blood Microparticles in Serpentine Lab-on-a-Disc Microchannels: A Numerical Study

Precise, sheathless manipulation of blood microscale components remains a central challenge in microfluidics, particularly for Lab-on-a-Disc (LOD) platforms where inertial, rotational, and electrokinetic effects coexist. This simulation study proposes a two-phase particle-handling strategy that integrates rotation-assisted inertial focusing with high-frequency dielectrophoretic (DEP) sorting inside serpentine microchannels. In phase I, three channel geometries─an asymmetric sinusoidal, symmetric sinusoidal, and rectangular layout─were systematically evaluated to determine their ability to confine 3 μm particles using inertial lift, Dean vortices, and rotation-induced centrifugal and Coriolis forces. The asymmetric sinusoidal design produced the strongest hydrodynamic ordering, achieving focusing efficiencies above 96%, especially when combined with higher inlet velocity, narrow channel width, and increased serpentine turns. Rotational actuation further enhanced focusing, with the combined centrifugal–Coriolis contribution improving performance from ∼34% (no rotation) to ∼64% at 800 rad/s. In phase II, rotation was removed and the prefocused stream was directed into a DEP electrode array for label-free separation of red blood cells (RBCs) and platelets (PLTs). Here, the rectangular geometry─despite being the weakest inertial focuser─outperformed the sinusoidal channels by stabilizing particle trajectories before entering regions of steep ∇|E|2. Under |20| V and 10 GHz actuation, the device achieved ∼95% platelet isolation with concurrent ∼25% RBC diversion, while higher inlet velocities reduced separation due to shorter DEP residence times. The combined findings establish a unified inertial-DEP mechanism for high-precision, pump-free blood component handling on LOD systems and provide design rules for next-generation point-of-care hematology platforms.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2026-05-28
DOI
https://doi.org/10.1021/acs.langmuir.6c01613
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geometry-Driven Inertial Focusing and Dielectrophoretic Separation of Blood Microparticles in Serpentine Lab-on-a-Disc Microchannels: A Numerical Study

Seyed Nezameddin Ashrafizadeh, Marzieh Razmjoo, Mahdi Khatibi
Langmuir
Microfluidic and Bio-sensing Technologies
article

Geometry-Driven Inertial Focusing and Dielectrophoretic Separation of Blood Microparticles in Serpentine Lab-on-a-Disc Microchannels: A Numerical Study

Seyed Nezameddin Ashrafizadeh, Marzieh Razmjoo, Mahdi Khatibi
article en

Abstract

Precise, sheathless manipulation of blood microscale components remains a central challenge in microfluidics, particularly for Lab-on-a-Disc (LOD) platforms where inertial, rotational, and electrokinetic effects coexist. This simulation study proposes a two-phase particle-handling strategy that integrates rotation-assisted inertial focusing with high-frequency dielectrophoretic (DEP) sorting inside serpentine microchannels. In phase I, three channel geometries─an asymmetric sinusoidal, symmetric sinusoidal, and rectangular layout─were systematically evaluated to determine their ability to confine 3 μm particles using inertial lift, Dean vortices, and rotation-induced centrifugal and Coriolis forces. The asymmetric sinusoidal design produced the strongest hydrodynamic ordering, achieving focusing efficiencies above 96%, especially when combined with higher inlet velocity, narrow channel width, and increased serpentine turns. Rotational actuation further enhanced focusing, with the combined centrifugal–Coriolis contribution improving performance from ∼34% (no rotation) to ∼64% at 800 rad/s. In phase II, rotation was removed and the prefocused stream was directed into a DEP electrode array for label-free separation of red blood cells (RBCs) and platelets (PLTs). Here, the rectangular geometry─despite being the weakest inertial focuser─outperformed the sinusoidal channels by stabilizing particle trajectories before entering regions of steep ∇|E|2. Under |20| V and 10 GHz actuation, the device achieved ∼95% platelet isolation with concurrent ∼25% RBC diversion, while higher inlet velocities reduced separation due to shorter DEP residence times. The combined findings establish a unified inertial-DEP mechanism for high-precision, pump-free blood component handling on LOD systems and provide design rules for next-generation point-of-care hematology platforms.

Langmuir
Separation Systems (United States) (US), Iran University of Science and Technology (IR)
Iran University of Science and Technology
Openalex Percentile: Top 10%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.