Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation

INTRODUCTION/AIMS: Conduction block (CB) at non-entrapment sites is an important electrodiagnostic (EDX) feature supporting acquired demyelinating neuropathies. However, anatomical variation may produce pseudoconduction block, mimicking true CB. After encountering a patient with median nerve pseudoconduction block due to anatomical variation, we aimed to assess the frequency of this variation, its impact on EDX interpretation, and the role of neuromuscular ultrasound (NMUS) in improving diagnostic accuracy. METHODS: We describe an index patient with median nerve pseudoconduction block in the forearm caused by anatomical variation, confirmed by ultrasound. We then retrospectively reviewed upper limb NMUS performed by a single EDX medicine specialist at University Hospitals Cleveland Medical Center. At the antecubital fossa, the distance between the midpoint of the brachial artery and the midpoint of the median nerve was measured. Available EDX values were reviewed for ultrasounds with marked nerve-artery separation. RESULTS: Sixty-eight patients were included. In all patients, the median nerve lay medial to the brachial artery (range: 2.5-26 mm). Seven patients (10.3%) had nerve-artery separation greater than 12.5 mm. Of these, five had available EDX data for retrospective review and three (60%) reported either complete or partial CB. DISCUSSION: True CB suggests significant pathology. NMUS can help distinguish pseudoconduction block from true CB and prevent misdiagnosis. When pseudoconduction block of the median nerve in the forearm is suspected, stimulation 15-25 mm medial to the brachial artery pulse, or slightly more medial and proximal (between the bicep tendon and brachialis muscle) may improve accuracy.

Authors

Institutions

Publication Details

Journal
Muscle & Nerve
Published
2026-05-28
DOI
https://doi.org/10.1002/mus.70285
Primary Topic
Peripheral Nerve Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation

Robert Adams, Bashar Katirji, Yajing Ye
Muscle & Nerve
Peripheral Nerve Disorders
article

Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation

Robert Adams, Bashar Katirji, Yajing Ye
article en

Abstract

INTRODUCTION/AIMS: Conduction block (CB) at non-entrapment sites is an important electrodiagnostic (EDX) feature supporting acquired demyelinating neuropathies. However, anatomical variation may produce pseudoconduction block, mimicking true CB. After encountering a patient with median nerve pseudoconduction block due to anatomical variation, we aimed to assess the frequency of this variation, its impact on EDX interpretation, and the role of neuromuscular ultrasound (NMUS) in improving diagnostic accuracy. METHODS: We describe an index patient with median nerve pseudoconduction block in the forearm caused by anatomical variation, confirmed by ultrasound. We then retrospectively reviewed upper limb NMUS performed by a single EDX medicine specialist at University Hospitals Cleveland Medical Center. At the antecubital fossa, the distance between the midpoint of the brachial artery and the midpoint of the median nerve was measured. Available EDX values were reviewed for ultrasounds with marked nerve-artery separation. RESULTS: Sixty-eight patients were included. In all patients, the median nerve lay medial to the brachial artery (range: 2.5-26 mm). Seven patients (10.3%) had nerve-artery separation greater than 12.5 mm. Of these, five had available EDX data for retrospective review and three (60%) reported either complete or partial CB. DISCUSSION: True CB suggests significant pathology. NMUS can help distinguish pseudoconduction block from true CB and prevent misdiagnosis. When pseudoconduction block of the median nerve in the forearm is suspected, stimulation 15-25 mm medial to the brachial artery pulse, or slightly more medial and proximal (between the bicep tendon and brachialis muscle) may improve accuracy.

Muscle & Nerve
University Hospitals of Cleveland (US), Louis Stokes Cleveland VA Medical Center (US), The Neurological Institute (US)
Good health and well-being
Openalex Percentile: Top 5%
Peripheral Nerve Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.