Microcirculation and Cerebrovascular Autoregulation in Patients With Mechanical Circulatory Support Devices

Acute brain injury (ABI) affects up to one-third of patients using mechanical circulatory support (MCS). In venoarterial extracorporeal membrane oxygenation (VA ECMO), ABI incidence (11%–40%) has not improved in two decades. Conversely, improvements in left ventricular assist devices (LVADs) have reduced the incidence of stroke, although it remains a major complication (10%–30%). The failure of MCS to ensure adequate cerebral protection may impair cerebrovascular autoregulation (CVAR) and disrupt microcirculatory function affected by reduced pulsatility, endothelial injury, acute perturbations in partial pressure of arterial carbon dioxide (PaCO<sub>2</sub>), and cerebral venous congestion. Here, we review evidence demonstrating that these factors alter microcirculatory dynamics and CVAR, thereby contributing to ABI through shared mechanistic pathways. Current methods for assessing CVAR are reviewed, including invasive indices such as the pressure reactivity index (PRx) from intracranial pressure monitoring and noninvasive metrics such as the cerebral oximetry index (COx) from near-infrared spectroscopy or flow-velocity correlations from transcranial Doppler. Each method is limited by feasibility, signal artifacts, and inter-modality variability. Our review identifies three priority areas for cerebral protection in MCS: preservation of pulse pressure, cautious titration of PaCO<sub>2</sub>, and integration of CVAR-informed blood pressure management. Preliminary evidence suggests that very low pulse pressure, rapid carbon dioxide correction, and persistent microcirculatory impairment are each associated with ABI risk. Future investigations should focus on validating bedside tools to assess CVAR and microcirculatory integrity, and on determining whether physiological targets derived from these measures can improve neurological outcomes in patients using MCS.

Authors

Institutions

Publication Details

Journal
Journal of Stroke
Published
2026-05-29
DOI
https://doi.org/10.5853/jos.2025.05428
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microcirculation and Cerebrovascular Autoregulation in Patients With Mechanical Circulatory Support Devices

S Y Cho, Han‐Gil Jeong, Zoe Soulé, Mingfeng Cao et al.
Journal of Stroke
Mechanical Circulatory Support Devices
article

Microcirculation and Cerebrovascular Autoregulation in Patients With Mechanical Circulatory Support Devices

S Y Cho, Han‐Gil Jeong, Zoe Soulé, Mingfeng Cao, Leon Fan, Siyu Wang, Yaman B. Ahmad, Glenn Whitman
article en

Abstract

Acute brain injury (ABI) affects up to one-third of patients using mechanical circulatory support (MCS). In venoarterial extracorporeal membrane oxygenation (VA ECMO), ABI incidence (11%–40%) has not improved in two decades. Conversely, improvements in left ventricular assist devices (LVADs) have reduced the incidence of stroke, although it remains a major complication (10%–30%). The failure of MCS to ensure adequate cerebral protection may impair cerebrovascular autoregulation (CVAR) and disrupt microcirculatory function affected by reduced pulsatility, endothelial injury, acute perturbations in partial pressure of arterial carbon dioxide (PaCO<sub>2</sub>), and cerebral venous congestion. Here, we review evidence demonstrating that these factors alter microcirculatory dynamics and CVAR, thereby contributing to ABI through shared mechanistic pathways. Current methods for assessing CVAR are reviewed, including invasive indices such as the pressure reactivity index (PRx) from intracranial pressure monitoring and noninvasive metrics such as the cerebral oximetry index (COx) from near-infrared spectroscopy or flow-velocity correlations from transcranial Doppler. Each method is limited by feasibility, signal artifacts, and inter-modality variability. Our review identifies three priority areas for cerebral protection in MCS: preservation of pulse pressure, cautious titration of PaCO<sub>2</sub>, and integration of CVAR-informed blood pressure management. Preliminary evidence suggests that very low pulse pressure, rapid carbon dioxide correction, and persistent microcirculatory impairment are each associated with ABI risk. Future investigations should focus on validating bedside tools to assess CVAR and microcirculatory integrity, and on determining whether physiological targets derived from these measures can improve neurological outcomes in patients using MCS.

Journal of StrokeVol. 28(2)
Johns Hopkins University (US), Johns Hopkins Medicine (US), Seoul National University Bundang Hospital (KR)
Openalex Percentile: Top 10%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.